工业电源
Click the link below to download the file.
Get your files as below link
Dowload link
15V
90W
6A
90-264 Vac
135 x 62 x 32 mm
5.31” x 2.44” x 1.26”
0.31 kg (0.68 lb)
Model | Description |
---|---|
MEA-090A15C 6-A | C14, 4 Pin DIN |
MEA-090A15C V-A | C14, tuning fork 90° |
MEA-090A15C W-A | C14, tuning fork |
15V
90W
6A
90-264 Vac
135 x 62 x 32 mm
5.31” x 2.44” x 1.26”
0.31 kg (0.68 lb)
Model | Description |
---|---|
MEA-090A15C 6-A | C14, 4 Pin DIN |
MEA-090A15C V-A | C14, tuning fork 90° |
MEA-090A15C W-A | C14, tuning fork |
输出电流
6A
|
输出电压
15V
|
输出电压范围
|
输出电压调整范围
-
|
输出功率
90W
|
输出电流调整范围
|
最大输出电压
|
缓冲时间
-
|
线电压调整率
± 0.5%
|
负载调整率
± 4.5%
|
纹波电压
-
|
开机时间
< 3000 ms @ 115 Vac & 230 Vac
|
保持时间
20 ms @ 115 Vac & 230 Vac
|
动态回应
± 5% @ 0-50% & 50-100% load; Slew rate 0.25 A/µs (@ 100 Hz, 50% Duty Cycle)
|
电容性负载启动
-
|
摇控开/关
-
|
保护设备
-
|
输入输出间电压骤降
-
|
残留波纹/PARD (20MHz)
-
|
残留波纹
-
|
最大功率
-
|
波纹与噪音
1%
|
CC 型号 LED系统电压范围
-
|
升压时间
< 50 ms @ 115 Vac & 230 Vac
|
峰值功率持续时间
-
|
峰值功率回复时间
-
|
额定输入电压
100-240 Vac
|
输入电压范围
90-264 Vac
|
最大输入电压
-
|
额定输入频率
50-60 Hz
|
输入频率范围
47-63Hz
|
额定直流输入电压
|
直流输入电压范围
-
|
输入电流
1.5 A @ 115 Vac, 0.75 A @ 230 Vac
|
输入功率(待机模式)
0.15 W @ 115 Vac & 230 Vac
|
100% 负载效率
-
|
最大涌入电流
50 A @ 115 Vac and 100 A @ 230 Vac
|
充电时间
-
|
功率因数
-
|
漏电流
0.1 mA @ 264 Vac NC1), 0.5 mA @ 264 Vac Single fault condition
|
额定电流
-
|
谐波失真总量
-
|
最大功率损耗
-
|
效率 @ 10% 负载
-
|
底座 / 外壳上盖
PC
|
|
指示灯
Green LED
|
|
冷却方式
-
|
|
输入端
IEC 60320 C14 socket
|
|
输出端
Tuning Fork type: 5.5 x 2.5 x 11 mm, 90° (for MEA-090A□C V-A)
4 Pin Din type, 180° (for MEA-090A□C 6-A) Tuning Fork type: 5.5 x 2.5 x 11 mm, 180° (for MEA-090A□C W-A) |
|
信号端
-
|
|
声压级(SPL)
-
|
|
输入/输出端
-
|
|
信号
-
|
|
安装导轨
-
|
|
电线
-
|
|
保护结构
-
|
|
端子台
-
|
|
重量
0.31 kg (0.68 lb)
|
尺寸
135 x 62 x
32 mm
5.31” x 2.44” x 1.26” |
振动测试(运行状态)
-
|
防震测试(运行状态)
-
|
运行温度
-10°C to +60°C
|
储存温度
-40°C to +85°C
|
功率降级
> 40°C de-rate power by 2.5% / °C
|
运行湿度
5-95% RH (Non-Condensing)
|
防震测试(非运行状态)
50 G, 11 ms, 3 shocks for each direction
|
振动测试(非运行状态)
5-500 Hz, 2.09 Grms, 20 minute for each three axis
|
储藏湿度
-
|
运行高度
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa)
|
污染程度
-
|
碰撞试验(运行状态)
-
|
过压类别
-
|
Corrosion
-
|
过压保护
150% max, Latch Mode
|
超负载/过电保护
180% max of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery)
|
过热保护
Latch Mode
|
短路保护
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
极性反接保护
-
|
防护等级
IP22
|
防震保护
Class I with C14 socket
|
输入端极性保护
-
|
电池极性保护
-
|
电池电压保护错误
-
|
深度放电保护
-
|
超负载保护
-
|
过电保护
-
|
内置保险丝
-
|
输入欠压保护
-
|
MTBF
> 1 million Hours based on Telecordia SR-332 (at 115Vac, Max. load and 25°C Ambient)
|
预计最长使用寿命
5 years (50% load @ 115Vac, 25°C)
|
Safety Certificate
-
|
电气安全
IEC 62368-1
IEC 60950-1 GB4943.1-2011, GB9254-2008, GB17625.1-2012 PSE J60950-1(H29) |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
医疗安全
IEC 60601-1 CB report, EN 60601-1
CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1 |
电隔离
Input to Output : 4000 Vac
Input to PE3) : 1500 Vac Output to PE3): 500 Vac |
工业控制设备
-
|
危险场所/ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
机器电气设备
-
|
用於电率安装的电气设备
-
|
安全特低电压
-
|
海事
-
|
材料与部件
RoHS Directive 2011/65/EU & EU 2015/863 Compliant
|
隔离电阻
-
|
PE 电阻
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016,
Medical Devices Regulations 2002 (UK MDR 2002) |
国家地区证书
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
IEC 62368-1
IEC 60950-1 GB4943.1, GB9254, GB17625.1 PSE J60950-1(H29) |
SIL3
-
|
15V
160W
10.67A
85-264 Vac
24V
300W
12.5A
90-264 Vac
24V
160W
6.67A
85-264 Vac
19V
160W
8.42A
85-264 Vac