Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
150W
6.25A
90-264Vac
165.1 x 76.1 x 31.5 mm
6.50” x 3.00” x 1.24”
0.47 kg (1.04 lb)
24V
150W
6.25A
90-264Vac
165.1 x 76.1 x 31.5 mm
6.50” x 3.00” x 1.24”
0.47 kg (1.04 lb)
Output Current
6.25A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
150W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5%
|
Load Regulation
± 3.0%
|
PARD
240 mV pk-pk @0 to 40°C
480 mV pk-pk @ -10 to 0°C |
Start-up Time
1000 ms typ. @ 115Vac
500 ms typ. @ 230Vac |
Hold-up Time
16ms @ nominal input, full load
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
40ms @ nominal input, full load
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.85 A @115Vac
1.0 A @230Vac |
Input Power (Standby Mode)
-
|
Efficiency at 100% load
90% typ. @115Vac
91% typ. @230Vac |
Inrush Current
No damage
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
0.25 mA @ 240Vac/50Hz
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
PC
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
C14
|
|
Output Terminal
4Pin Din
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.47 kg (1.04 lb)
|
Dimensions
165.1 x 76.1 x
31.5 mm
6.50” x 3.00” x 1.24” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-10°C to +60°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
>40°C de-rated by 2.5%/°C
|
Operating Humidity
5%-95% RH (non-condensing)
|
Shock Test (Non-Operating)
50G, 11ms, 1 shock for each direction
|
Vibration (Non-Operating)
5-500Hz, 2.09Grms, 20mins, one cycle for each three axis
|
Storage Humidity
-
|
Operating Altitude
5,000 meters (16400 feet)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
33V, Latch Mode
|
Overload / Overcurrent
120-180% , Latch Mode
|
Over Temperature
Latch Mode
|
Short Circuit
Latch Mode
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 300,000 hrs. per Telcordia SR-332 at Input: 115Vac, Output: 100% load, Ta: 25°C
|
Expected Cap Life Time
5 years (50% load @ 25°C)
|
Safety Certificate
-
|
Electrical Safety
IEC/EN 60950-1 ; IEC/UL/EN 62368-1
BSMI CNS 14336-1 CCC GB 4943.1 PSE J 62368-1 KC K 60950-1 |
CE
Comply with EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
I/P to O/P : 3000Vac
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
CISPR/EN/BS EN 55032 Class B
BSMI CNS13438 FCC Part 15 GB/T9254 KN32 |
Immunity
EN/BS EN 55024; KN35
|
Harmonic Current Emissions
IEC 61000-3-2 Class D ; GB 17625.1
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
65W
2.71A
90-264 Vac
12V
60W
5A
90-264 Vac
24V
300W
12.5A
90-264 Vac
15V
65W
4.33A
90-264 Vac