Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
15V
65W
4.33A
90-264Vac
115 x 50 x 29 mm
4.53” x 1.97” x 1.14”
0.25 kg (0.55 lb)
15V
65W
4.33A
90-264Vac
115 x 50 x 29 mm
4.53” x 1.97” x 1.14”
0.25 kg (0.55 lb)
Output Current
4.33A
|
Output Voltage
15V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
65W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5%
|
Load Regulation
± 4.5%
|
PARD
1%
|
Start-up Time
< 3000ms @ 115Vac & 230Vac
|
Hold-up Time
10ms typ. @ 115Vac
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 0-50% & 50-100% load; Slew rate 0.25A/µs (@ 100Hz, 50% Duty Cycle)
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50ms @ 115Vac & 230Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.5A @ 115Vac, 0.75A @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
-
|
Max Inrush Current
50A @ 115Vac and 100A @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
0.2mA @ 264Vac NC2), 0.5mA @ 264Vac SFC3)
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
PC
|
|
Indicator
Green LED
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.25 kg (0.55 lb)
|
Dimensions
115 x 50 x
29 mm
4.53” x 1.97” x 1.14” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-10°C to +60°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 40°C de-rate power by 2.5% / °C
|
Operating Humidity
10-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
Vibration (Non-Operating)
5-500Hz, 2.09Grms, 20 minute for each three axis
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
150% max, Latch Mode
|
Overload / Overcurrent
(max.)
180% max of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
IP22
|
Protection Against Shock
Class I
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
1 million Hours based on Telecordia SR-332 (at 115Vac, Max. load and 25°C Ambient)
|
Expected Cap Life Time
-
|
Safety Certificate
-
|
Electrical Safety
IEC 62368-1
IEC 60950-1 PSE J 62368-1 GB 4943.1-2022, GB/T 9254.1-2021, GB 17625.1-2012 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
|
Medical Safety
IEC 60601-1 CB report
EN 60601-1 CAN/CSA-C22.2 No. 60601-1 ANSI/AAMI ES60601-1 UL60601-1 |
Galvanic Isolation
Input to Output: 4000Vac
Input to PE: 1500Vac Output to PE: 500Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
IEC 62368-1
IEC 60950-1 PSE J 62368-1 GB 4943.1, GB/T 9254.1, GB 17625.1 |
SIL3
-
|
Emission
EN/BS EN 55011 Class B Compliance to EN/BS EN 55032, FCC Title 47: Class B
|
Immunity
-
|
Harmonic Current Emissions
IEC61000-3-2
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
65W
2.71A
90-264 Vac
24V
160W
6.67A
85-264 Vac
19V
65W
3.42A
90-264 Vac
24V
300W
12.5A
90-264 Vac