Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
300W
12.5A
90-264 Vac
200 x 100 x 43 mm
7.87” x 3.94” x 1.69”
1.06 kg (2.34 lb)
24V
300W
12.5A
90-264 Vac
200 x 100 x 43 mm
7.87” x 3.94” x 1.69”
1.06 kg (2.34 lb)
Output Current
12.5A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
300W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5%
|
Load Regulation
± 4.5%
|
PARD
240 mVp-p @ Rated load
|
Start-up Time
1500 ms typ. @ 115 Vac & 230 Vac
|
Hold-up Time
25 ms typ. @ 115 Vac
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
21.6-25.2 V @ 0-50% & 50-100% load;
Slew rate 0.25 A/µs (@ 50 Hz / 1 KHz, 50% Duty Cycle) |
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50 ms @ 115 Vac & 230 Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
4 A @ 100 Vac, 1 A @ 230 Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
91% typ. @ 115 Vac, 93% typ. @ 230 Vac
|
Inrush Current
50 A @ 115 Vac and 100 A @ 230 Vac
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
0.2 mA @ 264 Vac NC , 0.3 mA @ 264 Vac SFC
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
79%
|
Case Chassis / Cover
PC
|
|
Indicator
Green LED
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
Input: IEC 60320 C14 socket
Output: MOLEX 39-01-2060 |
|
Unit Weight
1.06 kg (2.34 lb)
|
Dimensions
200 x 100 x
43 mm
7.87” x 3.94” x 1.69” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-10°C to +60°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 40°C de-rate power by 2.5% / °C
|
Operating Humidity
10-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
Half-Sine Wave 50G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
Random 5-500 Hz, 2.09 Grms, 20 minutes for each three axis
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
130% max of rated output voltage, Latch Mode
|
Overload / Overcurrent
160% max of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery)
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
IP22
|
Protection Against Shock
Class I
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
500K Hours based on Telecordia SR-332 (at 100 Vac, Max. load and 25°C Ambient)
|
Expected Cap Life Time
5 Years (115 Vac, 100% load @ 25°C)
|
Safety Certificate
-
|
Electrical Safety
-
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A1: 2013 + A12: 2014+ A2: 2021 & EN 60601-1-2: 2015 + A1: 2021
|
Medical Safety
IEC 60601-1 CB Report, EN 60601-1
CAN/CSA-C22.2 No.60601-1 ANSI/AAMI ES 60601-1 |
Galvanic Isolation
Input to Output: 4000 Vac
Input to PE: 1500 Vac Output to PE: 500 Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
EN IEC 62368-1, UL 62368-1, CAN/CSA C22.2 No. 62368
PSE J 62368-1, GB 4943.1, GB/T 9254.1, GB 17625.1 BSMI CNS 15598-1 KC 62368-1 IS 13252 (Part 1) |
SIL3
-
|
Emission
EN/BS EN 55011, EN/BS EN 55032 : Class B
CISPR 11, CISPR 32 : Class B Compliance to FCC Title 47: Class B KS C 9832 |
Immunity
-
|
Harmonic Current Emissions
IEC 61000-3-2 Meet Class A and Class D limit
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
ESD Immunity
IEC 61000-4-2
Level 4 Criteria A Air Discharge: 15 kV Contact Discharge: 8 kV |
Radiated Immunity
IEC 61000-4-3
Criteria A 80 MHz-2700 MHz, 10 V/m AM modulation 385 MHz-5785 MHz, 28 V/m Pulse mode and other modulation |
EFT
IEC 61000-4-4
Level 3 Criteria A : 2 kV |
Surge
IEC 61000-4-5
Level 3 Criteria A Common Mode : 2 kV Differential Mode : 1 kV |
Conducted Immunity
IEC 61000-4-6
Level 2 Criteria A 150 kHz-80 MHz, 3 Vrms, 6 Vrms at ISM bands and Amateur radio bands |
Magnetic Field
IEC 61000-4-8
Criteria A Magnetic field strength 30 A/m |
Voltage Dips
IEC 61000-4-11
Criteria A 0% UT, 0.5 cycle (10 ms) 0° /45° /90° /135° /180° /225° /270° /315° /360° Criteria B 0% UT, 1 cycle (20 ms), 0° Criteria A 70% UT, 25 cycle (500 ms), 0° Criteria B 0% UT, 250 cycle (5000 ms), 0° |
Component Power Supply for General Use
-
|
19V
160W
8.42A
85-264 Vac
15V
160W
10.67A
85-264 Vac
12V
150W
12.5A
85-264 Vac
24V
65W
2.71A
90-264 Vac