Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
36W
1.5A
85-264 Vac
87.5 x 35.0 x 55.0 mm
3.44” x 1.38” x 2.17”
0.13 kg (0.29 lb)
24V
36W
1.5A
85-264 Vac
87.5 x 35.0 x 55.0 mm
3.44” x 1.38” x 2.17”
0.13 kg (0.29 lb)
Output Current
1.5A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
21.6-26.4 Vdc
|
Output Power
36W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% @ 115 Vac & 230 Vac
|
Load Regulation
± 0.5%
|
PARD
< 150 mVpp @ 0°C to +70°C
< 450 mVpp @ -30°C to 0°C |
Start-up Time
300 ms typ. @ 115 Vac & 230 Vac
|
Hold-up Time
14 ms typ. @ 115 Vac & 70 ms typ. 230 Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 Vac & 230 Vac input, 10-100% load
(Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz) |
Start-up with Capacitive Loads
8,000 µF max.
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30 ms typ. @ 115 Vac & 230 Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Peak Power
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
85-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
< 0.9 A @ 115 Vac
< 0.5 A @ 230 Vac |
Input Power (Standby Mode)
-
|
Efficiency at 100% load
87.5% typ. @ 115 Vac
89.0% typ. @ 230 Vac |
Inrush Current
40 A typ. @ 230 Vac
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 0.25 mA @ 240 Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
0% load:
0.1 W typ. @ 115 Vac & 230 Vac |
Efficiency @ 10% load
-
|
Case Chassis / Cover
Plastic
|
|
Indicator
Green LED DC OK
|
|
Cooling System
Convection
|
|
Input Terminal
M2.5 x 2 Pins (Rated 300 V / 16 A)
|
|
Output Terminal
M2.5 x 2 Pins (Rated 300 V / 16 A)
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input: AWG 24-12
Output: AWG 24-12 |
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.13 kg (0.29 lb)
|
Dimensions
87.5 x 35.0 x
55.0 mm
3.44” x 1.38” x 2.17” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2 G; 10 min per cycle, 60 min for X, Y, Z direction
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Temperature: > 50°C de-rate power by 2% / °C
Input Voltage: < 100Vac de-rate power by 1% / Vac |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (6,560 ft)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
(Compliance to EN 62477-1 OVC III with 2,000 Meters altitude) |
Corrosion
-
|
Acoustic Noise
-
|
Overvoltage
< 36 V, SELV Output Latch Mode
|
Overload / Overcurrent
101 - 150% of rated load current, Auto-recovery
Continuous current limit Mode (Vo > 80%) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
Class II (No Primary Earth connection is required)
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
T3.15 A / 250 V
|
Insufficient Input Voltage Protection
-
|
MTBF
Telcordia SR-332: > 700,000 hrs
I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
10 years (115 Vac & 230 Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1, IEC/EN/BS EN 61010-1/-2-201, IEC 60335-1, IEC/EN/BS EN 61558-1/-2-16
TUV Bauart: EN/BS EN 62368-1, EN/BS EN 60335-1 UL/cUL: UL 62368-1, UL 61010-1/-2-201 EAC: TP TC 004/2011 BSMI: CNS 15598-1 BIS: IS 13252 (Part 1) CCC: GB 4943.1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output 4.0 kVac
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
CISPR 32, EN/BS 55032, AS/NZS CISPR32, EN 61204-3, KS C 9832
Compliance to FCC Title 47, EN/BS 61000-6-3 , EN/BS EN 61000-6-4: Class B |
Immunity
EN/BS 55035, KS C 9835, EN/BS 61000-6-2
Compliance to EN 61000-6-1 |
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
EN 61204-3
|
24V
75W
3.125A
85-264Vac
24V
120W
5A
90-264Vac
24V
120W
5A
90-264 Vac
24V
60W
2.5A
85-264 Vac
24V
91.92W
3.83A
85-264 Vac