24V
120W
5A
90-264 Vac
123.6 x 30 x 116.8 mm
4.87” x 1.18” x 4.60”
0.5 kg (1.10 lb)
Model | Description |
---|---|
DRF-24V120W1GTA | Spring Clamp Terminal |
24V
120W
5A
90-264 Vac
123.6 x 30 x 116.8 mm
4.87” x 1.18” x 4.60”
0.5 kg (1.10 lb)
Model | Description |
---|---|
DRF-24V120W1GTA | Spring Clamp Terminal |
Output Current
5A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
24-28 Vdc
|
Output Power
120W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% @ 115 Vac & 230 Vac
|
Load Regulation
± 1.0%
|
PARD
< 100 mVpp @ 0°C to +70°C
< 300 mVpp @ -30°C to 0°C |
Start-up Time
300 ms typ. @ 115 Vac & 230 Vac
|
Hold-up Time
35 ms typ. @ 115 Vac & 230 Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz)
|
Start-up with Capacitive Loads
10,000 µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30 ms typ. @ 115 Vac & 230 Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
127-375 Vdc
|
Input Current
1.2 A typ. @ 115 Vac, 0.6 A typ. @ 230 Vac
|
Input Power (Standby Mode)
0.5 W max @ 115 Vac & 230 Vac
|
Efficiency at 100% load
93.5 typ. @ 230 Vac
|
Max Inrush Current
40 A typ. @ 230 Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 115 Vac & > 0.92 @ 230 Vac
|
Leakage Current
< 0.5 mA @ 240 Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Metal
|
|
Indicator
Green LED DC OK
|
|
Cooling System
Convection
|
|
Input Terminal
3 Pins (Rated 600 V / 30 A)
|
|
Output Terminal
3 Pins (Rated 600 V / 30 A)
|
|
Signal Terminal
2 Pins (Rated 300 V / 6 A)
|
|
Noise Sound Pressure Level (SPL)
< 25 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input: AWG 18-12
Output: AWG 18-12 DC OK: AWG 22-16 |
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.5 kg (1.10 lb)
|
Dimensions
123.6 x 30 x
116.8 mm
4.87” x 1.18” x 4.60” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10Hz to 500Hz; 4G peak; 60 min per axis for all X, Y, Z directions
|
Shock Test (Operating)
-
|
Operating Temperature
-30°C to +70°C (-40°C Cold Start)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Temperature: > 60°C de-rate power by 2.5 % / °C
Input Voltage: < 100Vac de-rate power by 1% / Vac |
Operating Humidity
5 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Corrosion
-
|
Overvoltage
<34 V, SELV Output, Latch Mode
|
Overload / Overcurrent
105 - 150% of rated load current, Auto-recovery
Continuous current limit Mode (Vo > 80%) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
T3.15 A / 250 V
|
Insufficient Input Voltage Protection
-
|
MTBF
Telcordia SR-332: > 700,000 hrs
I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
10 years (115 Vac & 230 Vac, 50% load @ 50°C)
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1/-2-201
TUV Bauart: EN/BS EN 62368-1, EN/BS EN 61010-1/-2-201 UL/cUL: UL 62368-1, UL 61010-1/-2-201 EAC: TP TC 004/2011 BSMI: CNS14336-1 CCC: GB4943.1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 4.0 kVac
Input to Ground: 2.0 kVac Output to Ground: 1.5 kVac Output to DC OK: 500 Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3, KS C 9832 Compliance to FCC Title 47, EN 61000-6-3 : Class B |
Immunity
EN/BS EN 55035, KS C 9835, EN/BS EN 61000-6-2
Compliance to EN 61000-6-1 |
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A & Class D
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
48V
120W
2.5A
90-264 Vac
12V
85.2W
7.1A
85-264 Vac
48V
960W
20A
3 x 320-575 Vac
48V
92.16W
1.92A
85-264 Vac