Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V
75W
6.25A
85-264Vac
123.6 x 27 x 102 mm
4.87” x 1.06” x 4.02”
0.22 kg (0.49 lb)
Model | Description |
---|---|
DRL-12V75W1AZR | Conformal coating |
12V
75W
6.25A
85-264Vac
123.6 x 27 x 102 mm
4.87” x 1.06” x 4.02”
0.22 kg (0.49 lb)
Model | Description |
---|---|
DRL-12V75W1AZR | Conformal coating |
Output Current
6.25A
|
Output Voltage
12V
|
Output Voltage Range
75Vdc
|
Output Voltage Adjustment Range
10.8-13.2Vdc
|
Output Power
75W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 0.5% (@ 85-264Vac, 100% load)
|
Load Regulation
< 1% (0-100% load)
|
PARD
< 120mVpp @ > -10°C to +70°C
< 360mVpp @ ≤ -10°C to -30°C |
Start-up Time
1200ms typ. @ 115Vac (100% load)
1000ms typ. @ 230Vac (100% load) |
Hold-up Time
16ms typ. @ 115Vac (100% load)
60ms typ. @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115Vac & 230Vac input, 0-50%, 50-100% load
(Slew Rate: 2.5A/μS, 50% duty cycle @ 100Hz & 1KHz) |
Start-up with Capacitive Loads
5,000µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30ms typ. @ nominal input (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
120-375 Vdc
|
Input Current
1.4A typ. @ 115Vac, 0.9A typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
87.5% typ. @ 230Vac
|
Max Inrush Current
50A typ. @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 1mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Plastic
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.22 kg (0.49 lb)
|
Dimensions
123.6 x 27 x
102 mm
4.87” x 1.06” x 4.02” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6m/s² (2G peak); displacement of 0.35mm; 10 min per cycle, 60 min for X direction
|
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
|
Operating Temperature
-20°C to +70°C (-30°C Cold Start)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-10°C to -20°C de-rate power by 1% / °C
> 40°C de-rate power by 1.67% / °C @ 115Vac > 50°C de-rate power by 2.5% / °C @ 230Vac Input Voltage: <100Vac de-rate power by 1.33% / Vac |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz; 2.09Grms; 20 min per axis for all X, Y, Z directions
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Corrosion
-
|
Overvoltage
<18V, SELV Output, Latch Mode
|
Overload / Overcurrent
105 - 133% of rated load current, Constant current limit, Auto-recovery
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
Telcordia SR-332: > 700,000 hrs
I/P: 100Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1
TUV Bauart: EN 62368-1 UL/cUL: UL 62368-1, UL 61010-1/-2-201 BSMI: CNS14336-1 EAC: TP TC 004/2011 KC: K60950-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 2.0KVac Output to Ground: 0.5KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, EN/BS EN 55011, AS/NZS CISPR32: Class B; GB9254.1 Compliance with: EN/BS EN 61000-6-3 |
Immunity
EN/BS EN 55035, EN/BS EN 55024 Compliance with: EN/BS EN 61000-6-1
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A; GB17625.1
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
24V
91.92W
3.83A
85-264 Vac
15V
240W
16A
90-264Vac
24V
480W
20A
85-276 Vac
48V
480W
10A