Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
15V
240W
16A
90-264Vac
123.6 x 40 x 116.8 mm
4.87” x 1.57” x 4.60”
0.62 kg (1.37 lb)
Model | Description |
---|---|
DRL-15V240W1ENA | Conformal coating |
15V
240W
16A
90-264Vac
123.6 x 40 x 116.8 mm
4.87” x 1.57” x 4.60”
0.62 kg (1.37 lb)
Model | Description |
---|---|
DRL-15V240W1ENA | Conformal coating |
Output Current
16A
|
Output Voltage
15V
|
Output Voltage Range
13.5-16.5Vdc
|
Output Voltage Adjustment Range
13.5-16.5 Vdc
|
Output Power
240W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% @ 115Vac & 230Vac
|
Load Regulation
± 1.0%
|
PARD
< 120mVpp @ 0°C to +70°C
< 360mVpp @ -30°C to 0°C |
Start-up Time
500ms typ. @ 115Vac & 230Vac
|
Hold-up Time
20ms typ. @ 115Vac (100% load)
20ms typ. @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
|
Start-up with Capacitive Loads
8,000µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30ms typ. @ 115Vac & 230Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
2.5A typ. @ 115Vac, 1.3A typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
87.0% typ. @ 230Vac
|
Inrush Current
40A typ. @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 115Vac & 230Vac
|
Leakage Current
< 0.75mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminum / SGCC
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
3 Pins (Rated 300V/30A)
|
|
Output Terminal
4 Pins (Rated 300V/20A)
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.62 kg (1.37 lb)
|
Dimensions
123.6 x 40 x
116.8 mm
4.87” x 1.57” x 4.60” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction
|
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
|
Operating Temperature
-30°C to +70°C (-40°C Cold Start)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 40°C de-rate power by 1.67 % / °C @115Vac > 50°C
de-rate power by 2.5 % / °C @230Vac |
Operating Humidity
20 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Corrosion
-
|
Overvoltage
< 21.75V, SELV Output, Latch Mode
|
Overload / Overcurrent
105 - 150% of rated load current, Auto-recovery
Continuous current limit Mode (Vo>80%) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
T4 A / 250 V
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
10 years (230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1
TUV Bauart: EN 62368-1 UL/cUL: UL 62368-1 CCC: GB4943.1 BSMI: CNS14336-1 EAC: TP TC 004/2011 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3 Compliance to FCC Title 47, EN/BS EN 61000-6-3: Class B |
Immunity
EN/BS EN 55035, EN/BS EN 61000-6-2
Compliance to EN/BS EN 61000-6-1 |
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
IEC 61000-4-2
|
Radiated Immunity
IEC 61000-4-3
|
EFT
IEC 61000-4-4
|
Surge
IEC 61000-4-5
|
Conducted Immunity
IEC 61000-4-6
|
Magnetic Field
IEC 61000-4-8
|
Voltage Dips
IEC 61000-4-11
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
48V
92.16W
1.92A
85-264 Vac
24V
60W
2.5A
85-264 Vac
12V
54W
4.5A
85-264 Vac
12V
24W
2A
85-264 Vac