Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
960W
40A
3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase)
124 x 110 x 128.6 mm
4.88” x 4.33” x 5.06”
2.3kg (5.07 lb)
24V
960W
40A
3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase)
124 x 110 x 128.6 mm
4.88” x 4.33” x 5.06”
2.3kg (5.07 lb)
Output Current
40A
|
Output Voltage
24V
|
Output Voltage Range
24-28Vdc
|
Output Voltage Adjustment Range
24-28Vdc
|
Output Power
960W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
10mV (@ 3 x 320-575Vac input, 100% load)
|
Load Regulation
80mV (@ 3 x 320-575Vac input, 0-100% load)
|
PARD
100mVpp Max.
|
Start-up Time
1,000ms @ 24V, 40A
|
Hold-up Time
50.4ms @ 24V, 20A
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 1.5-100% load
|
Start-up with Capacitive Loads
40,000μF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
65ms
|
Power Boost Duration
5 seconds Typ.
7 seconds Max. |
Power Boost Recovery Time
17 seconds Typ.
|
Nominal Input Voltage
3 x 400-500Vac
|
Input Voltage Range
3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase)
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
450-800Vdc
|
Input Current
1.53A @ 24V, 40A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
95.75% @ 24V, 40A
|
Inrush Current
14.2A
|
Charging Time
-
|
Power Factor at 100% load
0.95 @ 24V, 40A
|
Leakage Current
< 0.62mA / 0.64mA @ 3 x400Vac, 50Hz, TN/TT / IT system
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium
|
|
Indicator
Green LED DC OK
Red LED Overload |
|
Cooling System
Convection
|
|
Input Terminal
4 Pins (Rated 600V/35A)
|
|
Output Terminal
4 Pins (Rated 300V/65A)
|
|
Signal Terminal
5 Pins (Rated 300V/12A)
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
2.3kg (5.07 lb)
|
Dimensions
124 x 110 x
128.6 mm
4.88” x 4.33” x 5.06” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-25°C to +70°C (Cold start -40°C)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Vertical Mounting: 3-Phase : > 60°C de-rate power by 2.5% / °C 2-Phase: > 50°C de-rate power by 2.5% / °C
Horizontal Mounting : 3-Phase: > 40°C de-rate power by 1.67% / °C 2-Phase: > 40°C de-rate power by 2% / °C |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
|
Storage Humidity
-
|
Operating Altitude
OVC III : 0 to 2,500 Meters (8,200 ft.)
OVC II : 2,500 to 6,000 Meters (19,680 ft.), 0 to 5,000 Meters (16,400 ft.), 0 to 3,000 Meters (9,840 ft.) |
Pollution Degree
2
|
Bump Test (Operating)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
< 32V, SELV Output, Hiccup Mode, Non-Latching (Auto- Recovery)
|
Overload / Overcurrent
150-200% of rated load current, Constant current, Hiccup Mode (Auto-Recovery)
|
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
568,300 hrs. as per Telcordia SR-332
I/P: 3 x 400Vac, O/P: 24V, 40A, Ta: 25°C |
Expected Cap Life Time
368,800 hrs. @ I/P: 3 x 400Vac, O/P: 24V, 20A, Ta: 25°C
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 62368-1, EN 61558-1, EN 61558-2-16, EN 61010-1, EN 61010-2-201
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1, IEC 61558-1, IEC 61558-2-16, IEC 61010-1, IEC 61010-2-201 UKCA: BS EN 62368-1, BS EN 61558-1, BS EN 61558-2-16, BS EN 61010-1, BS EN 61010-2-201 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
EN/BS EN 60204-1 (over voltage category III)
|
Electrical Equipment for Use in Electrical Power Installations
IEC/EN/BS EN 62477-1 / IEC 62103
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
DNV GL: Germanischer Lloyd classified
ABS: American Bureau for Shipping PDA Environmental category: C, EMC2 |
Material and Parts
-
|
Isolation Resistance
> 5MOhm Input to Output, 500Vdc
|
PE Resistance
< 0.1Ohm
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B |
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 55035, EN 61000-6-2
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
15V
240W
16A
90-264Vac
12V
54W
4.5A
85-264 Vac
12V
15W
1.25A
85-264 Vac
12V
85.2W
7.1A
85-264 Vac