Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
120W
5A
88-264Vac
124 x 40 x 117 mm
4.88” x 1.57” x 4.61”
0.58 kg (1.28 lb)
Model | Description |
---|---|
DRP-24V120W1CBN | Certified for AC & DC input |
24V
120W
5A
88-264Vac
124 x 40 x 117 mm
4.88” x 1.57” x 4.61”
0.58 kg (1.28 lb)
Model | Description |
---|---|
DRP-24V120W1CBN | Certified for AC & DC input |
Output Current
5A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
24-28Vdc
|
Output Power
120W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
0.5% (@ 88-264Vac input, 100% load)
|
Load Regulation
1.0% (@ 88-264Vac input, 0-100% load)
|
PARD
100mVpp Max.
|
Start-up Time
1,500ms Max. @ 24V, 5A
|
Hold-up Time
35ms Typ. @ 24V, 5A
20ms Min. @ 24V, 5A |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load
Slew rate 0.1A/µs (@ 5Hz, 50Hz & 1kHz, 50% Duty Cycle) |
Start-up with Capacitive Loads
10,000µF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
60ms Max. @ 24V, 5A
|
Power Boost Duration
5 seconds Min.
|
Power Boost Recovery Time
18 seconds Typ.
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
88-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
100-375Vdc (Continuously operating, with safety approval according to IEC/EN/UL 60950-1)
88-100Vdc (With power de-rating) |
Input Current
1.18A Typ. @ 115 Vac, 0.61A Typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
89.92% Typ. @ 115Vac, 91.49% Typ. @ 230Vac
|
Inrush Current
(Cold Start)
12.4A Typ. @ 115Vac, 25.6A Typ. @ 230Vac, 35A Max. @ 115Vac, 70A Max. @ 230Vac |
Charging Time
-
|
Power Factor at 100% load
0.98 Typ. @ 115Vac, 0.95 Typ. @ 230Vac, 0.96 Min. @ 115Vac, 0.93 Min. @ 230Vac
|
Leakage Current
(Enclosure to Neutral)
< 0.20mA / 0.50mA: 110Vac, 50Hz, TN/TT system / IT system < 0.24mA / 0.60mA: 132Vac, 50Hz, TN/TT system / IT system < 0.47mA / 1.20mA: 264Vac, 50Hz, TN/TT system / IT system |
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
At 24V, 0A: 3.31W Typ. @ 115Vac, 3.20W Typ. @ 230Vac, 5.0W Max. @ 115Vac, 5.0W Max. @ 230Vac
At 24V, 5A: 13.46W Typ. @ 115Vac, 11.16W Typ. @ 230Vac, 14.0W Max. @ 115Vac, 13.0W Max. @ 230Vac |
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
3 Pins (Rated 600V/35A)
|
|
Output Terminal
4 Pins (Rated 300V/28A)
|
|
Signal Terminal
2 Pins (Rated 300V/28A)
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input: AWG 18-8
Output: AWG 18-12 Signal: AWG 18-12 |
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.58 kg (1.28 lb)
|
Dimensions
124 x 40 x
117 mm
4.88” x 1.57” x 4.61” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-25°C to +70°C (Cold start -40°C)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Vertical Mounting: > 60°C de-rate power by 2.5% / °C
Horizontal Mounting: > 40°C de-rate power by 1.67% / °C Input Voltage: AC input < 100Vac de-rate power by 0.83% / V DC input < 100Vdc de-rate power by 1.67% / V |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
|
Over Voltage Category
III (operating altitude 2,500 Meters)
II (operating altitude 5,000 Meters) According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
Corrosion
-
|
Overvoltage
28.8 - 35.2V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Overload / Overcurrent
125 – 170% of rated load current, Constant current, Hiccup Mode (Auto-Recovery)
|
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed): Load impedance ≤ 100mOhm
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
1,411,300 hrs.: I/P: 115Vac, O/P: 24V, 5A, Ta: 25°C
842,900 hrs.: I/P: 115Vac, O/P: 24V, 5A, Ta: 40°C |
Expected Cap Life Time
O/P: 24V, 5A, Ta: 25°C: 131,400hrs. @ 115Vac & 230Vac
O/P: 24V, 2.5A, Ta: 40°C: 131,400hrs. @ 115Vac & 230Vac O/P: 24V, 5A, Ta: 60°C: 21,100hrs. @ 115Vac, 32,700hrs. @ 230Vac O/P: 24V, 3.75A, Ta: 60°C: 29,700hrs.@ 115Vac, 47,300hrs. @ 230Vac |
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1 UKCA: BS EN 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 4.0 KVac
Input to Ground: 2.0 KVac Input to DC OK relay contact: 4.0 KVac Output to Ground: 1.5 KVac Output to DC OK relay contact: 0.5 KVac DC OK relay contact to PE: 1.5 KVac |
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
EN/BS EN 60204-1 (over voltage category III)
|
Electrical Equipment for Use in Electrical Power Installations
IEC/EN/BS EN 62477-1 / IEC 62103
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
< 0.1 Ohm
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B |
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-2
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
48V
92.16W
1.92A
85-264 Vac
15V
240W
16A
90-264Vac
12V
85.2W
7.1A
85-264 Vac
24V
36W
1.5A
85-264 Vac