Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
48W
2A
85-264Vac
100 x 32 x 100.6 mm
3.94” x 1.26” x 3.96”
0.22 kg (0.49 lb)
24V
48W
2A
85-264Vac
100 x 32 x 100.6 mm
3.94” x 1.26” x 3.96”
0.22 kg (0.49 lb)
Output Current
2A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
22-26Vdc
|
Output Power
48W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 1.0% (@ 85-264Vac input, 100% load)
|
Load Regulation
< 1.0% (@ 85-264Vac input, 0-100% load)
|
PARD
< 240mVpp
|
Start-up Time
< 3,000ms @ nominal input (100% load)
|
Hold-up Time
> 10ms @ 115Vac,
> 60ms @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 10-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
Start-up with Capacitive Loads
1,000µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50ms @ nominal input (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
125-250Vdc
|
DC Input Voltage Range
120-375Vdc
|
Input Current
< 1.40A @ 115Vac,
< 0.70A @ 230Vac |
Input Power (Standby Mode)
-
|
Efficiency at 100% load
> 87.0% @ 115Vac & 230Vac
|
Max Inrush Current
< 28A @ 115Vac,
< 56A @ 230Vac |
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 1mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
0% load: < 0.3W @ 115Vac & < 0.5W @ 230Vac
100% load: < 7.0W @ 115Vac & 230Vac |
Efficiency @ 10% load
-
|
Case Chassis / Cover
Plastic
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 40dBA
|
|
Input/Output Terminal
5 Pins (Rated 300V/15A)
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input / Output: AWG 20-14
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.22 kg (0.49 lb)
|
Dimensions
100 x 32 x
100.6 mm
3.94” x 1.26” x 3.96” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-25°C to +85°C
|
Power De-rating
Vertical / Horizontal: -20ºC to -10ºC de-rate power by 1% / ºC, -10ºC to 0ºC de-rate power by 2% / ºC, > 50ºC de-rate power by 2.5% / ºC
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC60068-2-27, 30G (300m/S for a duration of 18ms, 1 times per direction, 2 times in total
|
Vibration (Non-Operating)
IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 2,000 Meters (6,560 ft)
|
Pollution Degree
2
|
Bump Test (Operating)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
|
Over Voltage Category
III
According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) |
Corrosion
-
|
Overvoltage
< 32.4V, SELV Output, Latch Mode
|
Overload / Overcurrent
> 105~180% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 500,000 hrs. as per Telcordia SR-332 (I/P: 115Vac, O/P: 100% load, Ta: 25°C)
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1 UKCA : BS EN 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
CSA: CSA C22.2 No. 107.1-01 (File No. 181564) |
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
EN 60204-1 (over voltage category III)
|
Electrical Equipment for Use in Electrical Power Installations
IEC/EN/BS EN 62477-1
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
Generic Standards: CISPR32, EN/BS EN 55032, KN 32 CISPR11, EN/BS EN 55011, FCC Title 47: Class B |
Immunity
Generic Standards: EN/BS EN 55024, KN 35, EN/BS EN 61000-6-2
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
60W
2.5A
85-264 Vac
48V
480W
10A
3 x 320-575 Vac
12V
-
4.5A
85-264 Vac
48V
120W
2.5A
90-264 Vac