Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
200-550V
600W
2A
198-440Vac
285 x 100 x 49 mm
11.22” x 3.94” x 1.93”
2.2 kg (4.85 lb)
200-550V
600W
2A
198-440Vac
285 x 100 x 49 mm
11.22” x 3.94” x 1.93”
2.2 kg (4.85 lb)
Output Current
2A
|
Output Voltage
200-550V
|
Output Voltage Range
200-550Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
600W
|
Output Current Adjustment Range
0.7-2A
|
Max Output Voltage
600Vdc
|
Buffering Time
-
|
Line Regulation
-
|
Load Regulation
-
|
PARD
-
|
Start-up Time
-
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Peak Power
-
|
Nominal Input Voltage
220-400Vac
|
Input Voltage Range
198-440Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50/60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
2.85 A At 220 Vac, 25°C, 600 W output
1.54 A At 400 Vac, 25°C, 600 W output |
Input Power (Standby Mode)
0.40 W At 230 Vac/50 Hz, Dim OFF, in compliance with Erp (EU) 2019/2020
0.89 W At 400 Vac, Dim OFF |
Efficiency at 100% load
96.2% At 220 Vac, 25°C, 300 V/2 A
96.6% At 220 Vac, 25°C, 550 V/1.1 A 96.8% At 400 Vac, 25°C, 300 V/2 A output 97.5% At 400 Vac, 25°C, 550 V/1.1 A output |
Inrush Current
8A At 220 Vac,50% Apk to 50% Apk time: 2 ms
15A At 400 Vac,50% Apk to 50% Apk time: 2 ms |
Charging Time
-
|
Power Factor at 100% load
0.99 At 220 Vac, 25°C, 600 W output
0.98 At 400 Vac, 25°C, 600 W output |
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
8% At 220 Vac, 25°C, 300 V/2 A output
13% At 400 Vac, 25°C, 300 V/2 A output |
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminum case, color: anodized (Nature)
|
|
Indicator
-
|
|
Cooling System
Natural Convection
|
|
Input Terminal
Line(L): Brown, Neutral(N): Blue, PE: Yellow & Green,
SOOW & H07RN-F & 2PNCT, 3C/1.0 mm² (17AWG), Length: 300mm±25mm |
|
Output Terminal
Positive(V+): Brown, Negative(V-): Blue, PE: Yellow & Green,
SOOW & H07RN-F & 2PNCT, 3C/1.0 mm² (17AWG), Length: 240mm±25mm |
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24dBA at 30cm distance
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
2.2 kg (4.85 lb)
|
Dimensions
285 x 100 x
49 mm
11.22” x 3.94” x 1.93” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40 ~+60°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10% to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G);
30 min per axis for all X, Y, Z direction |
Storage Humidity
10% to 90% RH (Non-Condensing)
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Acoustic Noise
-
|
Overvoltage
-
|
Overload / Overcurrent
-
|
Over Temperature
-
|
Short Circuit
-
|
Reverse Polarity Protection
-
|
Degree of Protection
IP66
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
475 khrs at Ta=+45°C Telcordia SR-332
|
Expected Cap Life Time
50,000 hours applicable for 220 Vac to 400 Vac(50/60 Hz) @100% of load, @ Ta 45°C
|
Safety Certificate
ENEC:
EN 61347-2-13:2014, EN 61347-2-13/A1:2017 EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN IEC 62384:2020 RCM: AS 61347-2-13: 2018 AS/NZS 61347-1: 2016+A1 CB report. |
Electrical Safety
-
|
CE
-
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Radiated Emission EN 55015
Conducted Emission EN 55015 |
Immunity
-
|
Harmonic Current Emissions
EN61000-3-2, GB 17625.1
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
ESD Immunity
EN 61000-4-2
|
Radiated Immunity
-
|
EFT
EN 61000-4-4
|
Surge
(AC Mains)
EN 61000-4-5 - Common Mode: 10kV (Line to Earth, Neutral to Earth) - Differential Mode: 6kV (Line to Neutral) |
Conducted Immunity
-
|
Magnetic Field
EN 61000-4-3
|
Voltage Dips
EN 61000-4-11
|
Component Power Supply for General Use
-
|
200-550V
600W
2A
198-440Vac
60-200V
130W
0.2-1.05A
198-264Vac
80-310V
170W
0.2-1.05A
198-264Vac
35-150V
75W
0.2-1.05A
198-264Vac