Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
600W
25A
80-275Vac
203.1 x 101.6 x 40.6 mm
8.00” x 4.00” x 1.60”
1.1 kg (2.43 lb)
Model | Description |
---|---|
IMA-S600-24-ZYPLI | Standard version, remote ON/OFF setting OFF, parallel operation |
IMA-C600-24-ZYPLI | Conformal coated version, remote ON/OFF setting OFF, parallel operation |
IMA-S600-24-ZYPLY | Standard version, remote ON/OFF setting ON, parallel operation |
IMA-C600-24-ZYPLY | Conformal coated version, remote ON/OFF setting ON, parallel operation |
IMA-S600-24-ZYSLI | Standard version, remote ON/OFF setting OFF, single operation |
IMA-C600-24-ZYSLI | Conformal coated version, remote ON/OFF setting OFF, single operation |
24V
600W
25A
80-275Vac
203.1 x 101.6 x 40.6 mm
8.00” x 4.00” x 1.60”
1.1 kg (2.43 lb)
Model | Description |
---|---|
IMA-S600-24-ZYPLI | Standard version, remote ON/OFF setting OFF, parallel operation |
IMA-C600-24-ZYPLI | Conformal coated version, remote ON/OFF setting OFF, parallel operation |
IMA-S600-24-ZYPLY | Standard version, remote ON/OFF setting ON, parallel operation |
IMA-C600-24-ZYPLY | Conformal coated version, remote ON/OFF setting ON, parallel operation |
IMA-S600-24-ZYSLI | Standard version, remote ON/OFF setting OFF, single operation |
IMA-C600-24-ZYSLI | Conformal coated version, remote ON/OFF setting OFF, single operation |
Output Current
25A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
19.2-28.8V
|
Output Power
600W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
-
|
Load Regulation
-
|
PARD
< 1% peak to peak
|
Start-up Time
< 2.5 s (@ AC OFF to ON, max. load)
< 150 ms (@ REMOTE OFF to ON, max. load) |
Hold-up Time
20 msec nominal
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
< 5%
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
80-275Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
120-300Vdc
|
Input Current
9A @ 80Vac
5.7A @ 120Vdc |
Input Power (Standby Mode)
-
|
Efficiency at 100% load
92% @ 115Vac
94% @ 230Vac |
Inrush Current
< 20A
|
Charging Time
-
|
Power Factor at 100% load
0.9 (typical)
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
-
|
|
Indicator
-
|
|
Cooling System
Fan with variable speed control
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.1 kg (2.43 lb)
|
Dimensions
203.1 x 101.6 x
40.6 mm
8.00” x 4.00” x 1.60” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
When AC input voltage is < 90 Vac, the output power will be reduced by 6 W per 1 V.
|
Operating Humidity
< 95% (non-condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27 compliant, 50 g, 11 msec, 3 shocks for each direction
|
Vibration (Non-Operating)
IEC 60068-2-6 compliant, 2.09 Grms, 5 Hz to 500 Hz, 20 minutes per side (3 planes)
|
Storage Humidity
-
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
YES, latch mode
30V to 35V |
Overload / Overcurrent
YES, at 108% to 140% of nominal output current; auto recovery
|
Over Temperature
YES, auto recovery
|
Short Circuit
YES, auto recovery
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
500,000 hours (Telecordia SR-332, Issue 3, 25 °C, 90% confidence level)
|
Expected Cap Life Time
-
|
Safety Certificate
-
|
Electrical Safety
IEC 62368-1 (2014) Edition 2
UL 60950-1/CSA 22.2 No 60950-1, Edition 2 |
CE
-
|
Medical Safety
IEC 60601-1(2005), EN60601-1(2006)
ANSI/AAMI ES 60601-1(2005) CAN/CSA C22.2 No. 60601-1 (2008) |
Galvanic Isolation
Input to Output (Reinforced): 4000 Vac; 2 x MOPP
Input to Case (Basic): 1500 Vac; 1 x MOPP Output to Case (Basic): 1500 Vac; 1 x MOPP |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
48V
2000W
41.6A
80 - 275 Vac
24V
2500W
104.2A
85-264 Vac
48V
200W
-
90-264 Vac
48V
2500W
52.1A
85-264 Vac