Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V,12V,5V,3.3V,5V,-5V,-12V
350W
8A,9A,1.25A,8A,8A,0.25A,0.1A
90-264Vac
194 x 100 x 40.5 mm
7.64” x 3.94” x 1.59”
1.20 kg (2.65 lb)
12V,12V,5V,3.3V,5V,-5V,-12V
350W
8A,9A,1.25A,8A,8A,0.25A,0.1A
90-264Vac
194 x 100 x 40.5 mm
7.64” x 3.94” x 1.59”
1.20 kg (2.65 lb)
Output Current
8A,9A,1.25A,8A,8A,0.25A,0.1A
|
Output Voltage
12V,12V,5V,3.3V,5V,-5V,-12V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
350W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
±0.5%
|
Load Regulation
±10% (max.)
|
PARD
-
|
Start-up Time
1000ms @ 115 Vac
|
Hold-up Time
17ms @ 115 Vac / 60Hz
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 50-100% load
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
20ms (max.)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
6A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
82% @ 115Vac/60Hz
85% @ 230Vac/50Hz |
Inrush Current
No damage, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.90 min @ 115V & 230V
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
SECC (Steel, Electrogalvanized, Cold Rolled, Coil)
|
|
Indicator
-
|
|
Cooling System
Forced Cooling
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.20 kg (2.65 lb)
|
Dimensions
194 x 100 x
40.5 mm
7.64” x 3.94” x 1.59” |
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
|
Shock Test (Operating)
50G, 11ms, 3 shocks for each direction
|
Operating Temperature
0°C to +50°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
5,000 meters (16,400 feet)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
For +3.3V output, Maximum voltage < 4.8V
For +5V output, Maximum voltage < 7V For +12V1 & +12V2 outputs, Maximum voltage < 16V Protection Method: Latch Mode For +5Vsb output, Maximum voltage < 10V Protection Method: Latch Mode |
Overload / Overcurrent
For +3.3V output, Maximum current < 25A
For +5V output, Maximum current < 25A For +12V1/+12V2 output, Maximum current < 25A Protection Method: Latch Mode For +5Vsb output, Maximum current < 5A Protection Method: Auto-recovery Mode |
Over Temperature
Protection Method: Latch Mode
|
Short Circuit
+3.3V, +5V, +12V1 and +12V2, Protection Method: Latch Mode +5Vsb,
Protection Method: Auto-recovery |
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
-
|
Electrical Safety
IEC60950-1 (Ed.2,2005) & IEC 62368-1 CB report
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
Medical Safety
IEC 60601-1
EN60601-1 CAN/CSA-C22.2 No. 60601-1 ANSI/AAMI ES60601-1 |
Galvanic Isolation
Input to Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500 Vac Output to/Ground (1XMOPP): 1500 Vac (Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016
and Electromagnetic Compatibility Regulations 2016 Medical Devices Regulations 2002(UK MDR 2002) |
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN/BS EN 55011 & Compliant with EN/BS EN 55032, FCC Title 47:Class B
|
Immunity
-
|
Harmonic Current Emissions
IEC61000-3-2: Meet Class D limit
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
ESD Immunity
IEC61000-4-2
|
Radiated Immunity
IEC61000-4-3
IEC60601-1-2 |
EFT
IEC61000-4-4
|
Surge
IEC61000-4-5
|
Conducted Immunity
IEC61000-4-6
|
Magnetic Field
IEC61000-4-8
|
Voltage Dips
IEC60601-1-2
|
Component Power Supply for General Use
-
|
48V
2500W
52.1A
85-264 Vac
24V
200W
-
90-264 Vac
24V
2500W
104.2A
85-264 Vac
12V
200W
-
90-264 Vac