Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
48V
1500W
31.25A
90-264 Vac
204 x 127 x 40.5 mm
8.03” x 5.00” x 1.59”
1.5 kg (3.31 lb)
48V
1500W
31.25A
90-264 Vac
204 x 127 x 40.5 mm
8.03” x 5.00” x 1.59”
1.5 kg (3.31 lb)
Output Current
31.25A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
1500W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
1%
|
Load Regulation
2%
|
PARD
-
|
Start-up Time
1000 ms @ 115 Vac
500 ms @ 230 Vac |
Hold-up Time
16 ms @ 120 0W load, 115 Vac
12 ms @ 1500 W load, 230Vac |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ with 5-100% load change
|
Start-up with Capacitive Loads
6000uF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
1% pk-pk Vrated@ rated load, @25°C
|
LED System Voltage Range in CC Mode
-
|
Rise Time
<50ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
15A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
(typ.)
89% @ 115 Vac 92% @ 230 Vac |
Max Inrush Current
40 A @ 264 Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.99 @ 115 V/60 Hz, full load
0.98 @ 230 V/50 Hz, full load |
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
-
|
|
Indicator
Green LED
|
|
Cooling System
-
|
|
Input Terminal
M4.0 x 3 Pins (Rated 300V/25A)
|
|
Output Terminal
M3.5 x 4 Pins (Rated 300V/32A)
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
8 AWG * (2X)
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.5 kg (3.31 lb)
|
Dimensions
204 x 127 x
40.5 mm
8.03” x 5.00” x 1.59” |
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
|
Shock Test (Operating)
-
|
Operating Temperature
Absolute Maximum/Minimum Rating. -20°C to +70°C. Linear power derate from 100% load at 50°C, to 50% load at 70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
20-90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Main output 145% of rated normal voltage, Latch Mode
|
Overload / Overcurrent
Main output 135% of rated current, constant current
Standby 4.0A max with Hiccup Mode (Non-Latching, Auto-Recovery) |
Over Temperature
Latch Mode for Main output
|
Short Circuit
Hiccup Mode for Main output and Standby (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC62368-1 CB report
CB scheme: IEC60950-1 CB report TUV Bauart: EN/ BS EN 62368-1 UL/cUL: UL62368-1+CAN/CSA62368-1 CCC:GB4943.1-2022, GB9254-2021, GB17625.1-2012 CB scheme:IEC 60335-1 CB report, IEC 61558-1/ -2-16 CB report TUV Bauart: EN/ BS EN 60335-1, EN/ BS EN 61558-1 / -2-16 |
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
|
Medical Safety
CB scheme:IEC60601-1 3rd+A1+A2 edition CB report
TUV Bauart: EN/ BS EN 60601-1:2006 UL/cUL: ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1: (Ed.3.2005) |
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500 Vac Output to/Ground(1XMOPP): 1500 Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN/ BS EN 55011, EN/ BS EN 55032 : Class B
EN/ BS EN 55014-1 (for MEB-1K5A24T AAA) CISPR 11, CISPR 32 : Class B KS C 9832 Compliance to FCC Title 47 Class B |
Immunity
BS EN / EN 55035, KS C 9835, EN/ BS EN 55014-2
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2 Meet Class A limit
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
48V
200W
-
90-264 Vac
24V
2000W
83.3A
80 - 275 Vac
24V
1500W
62.5A
90-264 Vac
48V
2000W
41.6A
80 - 275 Vac