48V
2500W
52.1A
85-264 Vac
271 x 127 x 40.5 mm
10.67” x 5.00” x 1.59”
1.95 kg (4.30 lb)
Model | Description |
---|---|
MEB-2K5A48T NAA | Remote On/Off state: default ON |
MEB-2K5A48T RAA | Remote On/Off state: default OFF |
48V
2500W
52.1A
85-264 Vac
271 x 127 x 40.5 mm
10.67” x 5.00” x 1.59”
1.95 kg (4.30 lb)
Model | Description |
---|---|
MEB-2K5A48T NAA | Remote On/Off state: default ON |
MEB-2K5A48T RAA | Remote On/Off state: default OFF |
Output Current
52.1A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
2500W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 1%
|
Load Regulation
< 2%
|
PARD
-
|
Start-up Time
1200 ms typ. @ 1500 W load, 110 Vac
|
Hold-up Time
> 16 ms @ 2000 W load, 230 Vac
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ with 50-100% load change
|
Start-up with Capacitive Loads
6000 uF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
1% pk-pk Vrated @ rated load
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50 ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
85-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
< 16 A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
91.1% typ. @ 115 Vac
94.0% typ. @ 230 Vac |
Inrush Current
< 40 A @ 264 Vac, cold/hot start
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 115 V / 50 Hz, 230 V / 50 Hz, full load
|
Leakage Current
Earth Leakage Current: < 0.5 mA @ NC, 1 mA @ SFC
Touch Current: < 0.1 mA @ NC, 0.4 mA @ SFC |
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
< 0.75 W @ remote off status
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
-
|
|
Indicator
-
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.95 kg (4.30 lb)
|
Dimensions
271 x 127 x
40.5 mm
10.67” x 5.00” x 1.59” |
Vibration (Operating)
5-500 Hz, 2.09 Grms, 20 minutes for each three axis
|
Shock Test (Operating)
-
|
Operating Temperature
Absolute Maximum/Minimum Rating. -20°C to +70°C. Linear power derate from 100% load at 50°C, to 50% load at 70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
Pollution Degree
3 (for IEC 60335-1)
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Main output 145% of rated normal voltage, Latch Mode
Standby 125% of rated voltage, Latch Mode |
Overload / Overcurrent
Main output 130% of rated current, with Hiccup Mode (Non-Latching, Auto-Recovery)
Standby 3.2 A max with Hiccup Mode (Non-Latching, Auto-Recovery) |
Over Temperature
Hiccup Mode (Non-Latching, Auto-Recovery)
|
Short Circuit
Hiccup Mode for Main output and Standby (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
500 Khrs based on Telecordia SR-332 at 230 Vac, 2,500 W, 35 °C
|
Expected Cap Life Time
26,280 hrs at 230 Vac, 2,500 W, 25°C
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 60950-1 CB report, IEC 62368-1 CB report
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A1: 2013 + A2: 2021 & EN 60601-1-2: 2015+ A1:2021 |
Medical Safety
CB scheme: IEC 60601-1 CB report
TUV Bauart: IEC/EN 60601-1 UL/cUL: ANSI/AAMI ES 60601-1+CAN/CSA 60601-1 |
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground (1XMOPP): 1500 Vac Output to/Ground (1XMOPP): 1500 Vac (Type BF applicated rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN55011/ EN55032, FCC Title 47: Class B
|
Immunity
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
|
Harmonic Current Emissions
IEC 61000-3-2 Meet Class A limit
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
IEC 61000-4-11, IEC 60601-1-2
|
Component Power Supply for General Use
-
|
48V
1200W
25A
85-264Vac
48V
750W
-
85-264Vac
48V
1500W
31.25A