Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
504W
21A
90-264Vac
165.3 x 85.2 x 41 mm
6.51” x 3.35” x 1.61”
0.66 kg (1.46 lb)
Model | Description |
---|---|
MEB-500A24F AA | Remote On/Off, conformal coating |
24V
504W
21A
90-264Vac
165.3 x 85.2 x 41 mm
6.51” x 3.35” x 1.61”
0.66 kg (1.46 lb)
Model | Description |
---|---|
MEB-500A24F AA | Remote On/Off, conformal coating |
Output Current
21A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
21.6V~26.4V
|
Output Power
504W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
96mv max.
|
Load Regulation
150mv max.
|
PARD
< 300mVpp @ 0~+50°C
< 360mvVpp @-20~0°C. |
Start-up Time
800ms max.
|
Hold-up Time
16ms typ. @ 120Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
±10% @50-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 100Hz)
|
Start-up with Capacitive Loads
8,800μF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
5A typ.@ 120Vac , 2.6A typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
92% typ. @ 230Vac
|
Inrush Current
40A typ. @ 230Vac, Cold start, @ 25°C
|
Charging Time
-
|
Power Factor at 100% load
0.98 typ. @ 115Vac, 0.96 typ. @ 230Vac
|
Leakage Current
输入对PE(保护地线)漏电流(最大值): 0.25 mA @ NC, 0.5 mA @ SFC
Type BF应用输出对PE(保护地线)漏电流(最大值): 0.1 mA @ NC, 0.3 mA @ SFC |
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminum
|
|
Indicator
-
|
|
Cooling System
Built-in Fan
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
Sound Pressure Level (SPL) < 60dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
AWG 22-12
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.66 kg (1.46 lb)
|
Dimensions
165.3 x 85.2 x
41 mm
6.51” x 3.35” x 1.61” |
Vibration (Operating)
IEC60068-2-6, Sine Wave: 10Hz to 55Hz@19.6m/s2(2G peak); 10min per cycle, 60min per axis for all X,Y,Z direction
|
Shock Test (Operating)
IEC60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3shocks for each 3 directions
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-30°C to +80°C
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
|
Operating Humidity
20 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
0 to 3,000 Meters (9,840 ft.) - IEC 60601-1
0 to 5,000 Meters (16,400 ft.) - IEC 60950-1 & IEC 62368-1 |
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
115-140% (27.6 – 33.6V)
105-150% (5.25 – 7V) Protection mode: Latch OFF |
Overload / Overcurrent
>105% rated full load current, Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
Over Temperature
Protection mode: Latch OFF.
|
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with PE connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 Hrs. Based on Telecordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
3 years (115Vac, 100% load @ 50°C)
|
Safety Certificate
-
|
Electrical Safety
IEC 60950-1 & IEC 62368-1 CB report
TUV 60950-1 UL 60950-1 + CAN/CSA 60950-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
Medical Safety
IEC 60601-1 CB report
TUV EN 60601-1 UL 60601-1 + ANSI/AAMI ES60601-1 + CAN/CSA 60601-1 |
Galvanic Isolation
Input to Output (2XMOPP): 4.0KVac
Input to Earth (1XMOPP): 1.5KVac Output to Earth (1XMOPP): 1.5KVac (Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
RoHS Directive 2011/65/EU & EU/2015/863 Compliant
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016
and Electromagnetic Compatibility Regulations 2016 Medical Devices Regulations 2002(UK MDR 2002) |
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN/BS EN 55011 & compliant with EN/BS EN 55032, FCC Title 47:Class B
|
Immunity
-
|
Harmonic Current Emissions
Meet Class A limit
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
200W
-
90-264 Vac
36V
2500W
69.5A
85-264 Vac
48V
2500W
52.1A
85-264 Vac
24V
2500W
104.2A
85-264 Vac