Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
750W
31.25A
85-264Vac
177.8 x 101.6 x 40 mm
7.00” x 4.00” x 1.57”
1.1 kg (2.43 lb)
Model | Description |
---|---|
MEB-750A24B | Inlet Type: C14 inlet |
24V
750W
31.25A
85-264Vac
177.8 x 101.6 x 40 mm
7.00” x 4.00” x 1.57”
1.1 kg (2.43 lb)
Model | Description |
---|---|
MEB-750A24B | Inlet Type: C14 inlet |
Output Current
31.25A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
750W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
1%
|
Load Regulation
2%
|
PARD
-
|
Start-up Time
2000ms with AC turn on
|
Hold-up Time
12 ms @ 100% load, with nominal input range
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 50% load change
|
Start-up with Capacitive Loads
6000uF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
1% pk-pk Vrated@ rated load
|
LED System Voltage Range in CC Mode
-
|
Rise Time
<50ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
9 A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
Up to 94%
|
Inrush Current
40 A @ 264 Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
>0.95 @ rated load
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Enclosed
|
|
Indicator
-
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.1 kg (2.43 lb)
|
Dimensions
177.8 x 101.6 x
40 mm
7.00” x 4.00” x 1.57” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
Absolute Maximum/Minimum Rating.
-20°C to +70°C. Linear power derate from 100% load at50°C, to 50% load at 70°C |
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
5-500 Hz, 2G rms, 15 minute for each three axis
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Main output 145% of rated normal voltage, Latch Mode
Standby 125% of rated voltage, Latch Mode |
Overload / Overcurrent
Main output 130% of rated current for over 750ms max
Standby 3.2A max with Hiccup Mode(Non-Latching, Auto-Recovery) |
Over Temperature
Latch Mode for Main output
|
Short Circuit
Hiccup Mode for Main output and Standby (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
500 Khrs based on Telecordia SR-332
|
Expected Cap Life Time
Operating life (Minimum) at 115 Vac, 750 W, 25°C: 26,280 hrs
|
Safety Certificate
-
|
Electrical Safety
IEC 60950-1 CB report
IEC 62368-1 CB report TUV EN 62368-1 TUV EN 60950-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1 KC/KCC (for 24V) Home Appliance: IEC60335-1 CB report IEC61558-1 /-2-16 CB report TUV EN 60335-1 TUV EN 61558-1 /-2-16 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
Medical Safety
IEC 60601-1 CB report
TUV EN 60601-1 ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1 |
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground (1XMOPP): 1500 Vac Output to/Ground (1XMOPP): 1500 Vac (Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016, Medical Devices Regulations 2002 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN/BS EN 55011, EN/BS EN 55032: Class B
|
Immunity
-
|
Harmonic Current Emissions
IEC61000-3-2 Meet Class D limit
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
ESD Immunity
IEC61000-4-2
|
Radiated Immunity
IEC61000-4-3
|
EFT
IEC61000-4-4
|
Surge
IEC61000-4-5
|
Conducted Immunity
IEC61000-4-6
|
Magnetic Field
IEC61000-4-8
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
48V
2000W
41.6A
80 - 275 Vac
48V
2500W
52.1A
85-264 Vac
24V
200W
-
90-264 Vac
48V
200W
-
90-264 Vac