Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
35-150V
75W
0.2-1.05A
198-264Vac
133 x 77 x 40 mm
5.24” x 3.03” x 1.57”
0.55 kg (1.21 lb)
• Wireless configuration interface via NFC
• DALI-2 certified LED driver with Part 207/251/253
• Constant power mode design and wide range of output
current adjustable: 200mA - 1050mA
• Programable functions: AOC/CLO/MTP/EOL
• Autonomous dimming includes three “Smart Timer Dim”
Operate with Fixed Timer, Midnight Centric Timer and
Ratio Rescale Timer
• Corridor mode operate with a DALI master or GUI software
• Robustness protection against vibration, harsh operating
temperature and moisture with potting
• Override function is used to force the output dimming to the
given level in any of Smart Timer Dim modes at any given
time when DALI dimming command is received
• High Efficiency Up to 94%
• High surge immunity protection (10K V/ 6K V)
• Meet Zhaga dimension criteria
• Wireless configuration interface via NFC
• DALI-2 certified LED driver with Part 207/251/253
• Constant power mode design and wide range of output
current adjustable: 200mA - 1050mA
• Programable functions: AOC/CLO/MTP/EOL
• Autonomous dimming includes three “Smart Timer Dim”
Operate with Fixed Timer, Midnight Centric Timer and
Ratio Rescale Timer
• Corridor mode operate with a DALI master or GUI software
• Robustness protection against vibration, harsh operating
temperature and moisture with potting
• Override function is used to force the output dimming to the
given level in any of Smart Timer Dim modes at any given
time when DALI dimming command is received
• High Efficiency Up to 94%
• High surge immunity protection (10K V/ 6K V)
• Meet Zhaga dimension criteria
35-150V
75W
0.2-1.05A
198-264Vac
133 x 77 x 40 mm
5.24” x 3.03” x 1.57”
0.55 kg (1.21 lb)
Output Current
0.2-1.05A
|
Output Voltage
35-150V
|
Output Voltage Range
35-150Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
75W
|
Output Current Adjustment Range
|
Max Output Voltage
210Vdc
|
Buffering Time
-
|
Line Regulation
± 3% (@ 220-240Vac)
|
Load Regulation
± 5% (@ Min-Max output voltage)
|
PARD
-
|
Start-up Time
520~1000ms max. (@ 220-240Vac)
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
220-240Vac
|
Input Voltage Range
198-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
0.43A @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
92% @ 0.5A, 230Vac
90% @ 1.05A, 230Vac |
Inrush Current
20A/250uS @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 230Vac, 100% load
|
Leakage Current
< 0.7mA peak @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
< 20% @ 230Vac, 100% load
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Plastic
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.55 kg (1.21 lb)
|
Dimensions
133 x 77 x
40 mm
5.24” x 3.03” x 1.57” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +55°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
5 to 95% RH (Non-Condensing)
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
210Vrms, Luminaries will work normally when the fault is removed
|
Overload / Overcurrent
Reduce output current. Auto-Recovery when the fault is removed
|
Over Temperature
Reduce output current. Auto-Recovery when the fault is removed
|
Short Circuit
Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
50,000 hours @ lifetime case temperature
|
Expected Cap Life Time
830,000 hours @Ta=+55°C (as per Telcordia SR-332, total failure rate less than 10%)
|
Safety Certificate
-
|
Electrical Safety
IEC 61347-1, IEC 61347-2-13 (Built in)
EN 61347-1, EN 61347-2-13 |
CE
In conformance with EMC Directive and Low Voltage Directive
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
Compliance to EN 55015 Class B |
Immunity
Compliance to EN 61547
|
Harmonic Current Emissions
Class C (230Vac @ ≥ 50% load)
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
8-48V
22W
0.2-1.05A
198-264Vac
20-77V
40W
0.2-1.05A
198-264Vac