Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
150-550V
1400W
2A
198-440 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
Model | Description |
---|---|
EUCO-1K4200GIA | Control Interface: DALI-2 & D4i |
150-550V
1400W
2A
198-440 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
Model | Description |
---|---|
EUCO-1K4200GIA | Control Interface: DALI-2 & D4i |
Output Current
2A
|
Output Voltage
150-550V
|
Output Voltage Range
150-550Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
1400W
|
Output Current Adjustment Range
0.7-2A
|
Max Output Voltage
600Vdc
|
Buffering Time
-
|
Line Regulation
-
|
Load Regulation
-
|
PARD
-
|
Start-up Time
-
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
220-400 Vac
|
Input Voltage Range
198-440 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50/60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
7A At 220Vac, 25°C, 1400W output
4A At 400Vac, 25°C, 1400W output |
Input Power (Standby Mode)
0.3W At 230Vac, Dim OFF, in compliance with Erp (EU) 2019/2020
0.8W At 400Vac, Dim OFF |
Efficiency at 100% load
At 220Vac~400Vac,100% load
|
Inrush Current
15A At 220Vac,50%Apk to 50%Apk time: 2ms
25A At 400Vac,50%Apk to 50%Apk time: 2ms |
Charging Time
-
|
Power Factor at 100% load
0.99 At 220Vac, 25°C, 2100W output
0.97 At 400Vac, 25°C, 2100W output |
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
6% At 220Vac, 25°C, 350V/2A *3 channels output
10% At 400Vac, 25°C, 350V/2A *3 channels output |
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminum case, Dark Gray, compliance with C5 environment (ISO 9223)
|
|
Indicator
-
|
|
Cooling System
Natural Convection
|
|
Input Terminal
With the sign of L1, L2, PE
|
|
Output Terminal
With the sign of PE, NTC, V3+ V3-, V2+, V2-, V1+, V1-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
5.4 kg (11.90 lb)
|
Dimensions
500 x 152 x
77 mm
19.69” x 5.98” x 3.03” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40 ~+50°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10% to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
Storage Humidity
10% to 90% RH (Non-Condensing)
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
-
|
Overload / Overcurrent
-
|
Over Temperature
-
|
Short Circuit
-
|
Reverse Polarity Protection
-
|
Degree of Protection
IP66
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
475khrs. at Ta=+45°C Telcordia SR-332
|
Expected Cap Life Time
50,000 hours applicable for 220Vac to 400Vac(50/60Hz) @100% of load, @ Ta 45°C
|
Safety Certificate
ENEC:
EN 61347-2-13:2014, EN 61347-2-13/A1:2017 EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN IEC 62384:2020 UL Compliant ANSI / UL8750 2nd Ed., CSA C22.2 No.250.13, 4th Ed. RCM:AS 61347-2-13: 2018 AS/NZS 61347-1: 2016+A1 CB report. |
Electrical Safety
-
|
CE
EN 61347-2-13:2014, EN 61347-2-13/A1:2017
CE Declaration of Conformity. |
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
BS EN 61347-2-13: 2014+A1:2017
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Radiated Emission EN55015
Conducted Emission EN55015 |
Immunity
-
|
Harmonic Current Emissions
EN61000-3-2
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
ESD Immunity
EN 61000-4-2
|
Radiated Immunity
-
|
EFT
EN 61000-4-4
|
Surge
(AC Mains)
EN 61000-4-5 - Common Mode: 10kV4 (Line to Earth, Neutral to Earth) - Differential Mode: 10kV4 (Line to Neutral) |
Conducted Immunity
-
|
Magnetic Field
EN 61000-4-3
|
Voltage Dips
EN 61000-4-11
|
Component Power Supply for General Use
-
|
260-500V
1000W
1.4A
198-440Vac
260-500V
1500W
1.4A
198-440Vac
250-550V
2100W
2A
198~440 Vac
200-550V
600W
2A
198-440Vac