Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
260-500V
1500W
1.4A
198-440Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.6 kg (12.35 lb)
Model | Description |
---|---|
EUCO-1K5140GLA | Control Interface: DALI 2 |
260-500V
1500W
1.4A
198-440Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.6 kg (12.35 lb)
Model | Description |
---|---|
EUCO-1K5140GLA | Control Interface: DALI 2 |
Output Current
1.4A
|
Output Voltage
260-500V
|
Output Voltage Range
260-500Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
1500W
|
Output Current Adjustment Range
0.5-1.4A
|
Max Output Voltage
600Vdc
|
Buffering Time
-
|
Line Regulation
±1%
|
Load Regulation
±3%
|
PARD
-
|
Start-up Time
-
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
500W per channel, 1.5kW total
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 2s
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
220-400Vac
|
Input Voltage Range
198-440Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50/60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
7.2A @ 220Vac, 4.1A @ 400Vac
|
Input Power (Standby Mode)
<0.5W at 230Vac,in compliance with Erp (EU) 2019/2020
|
Efficiency at 100% load
95.2% @ 220Vac, 96% @ 400Vac
|
Inrush Current
<=25 A, pulse width<8mS @400Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 198-440Vac, full load
|
Leakage Current
< 1mA @ 400Vac
|
Nominal Current
-
|
Total Harmonic Distortion
<20% @ 198-440Vac, full load
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminum case
|
|
Indicator
-
|
|
Cooling System
Natural Convection
|
|
Input Terminal
Wago 264-103, with the sign of L, N, PE
|
|
Output Terminal
Wago 264-111, with the sign of PE, NTC, V3+ V3-, V2+, V2-, V1+, V1-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
5.6 kg (12.35 lb)
|
Dimensions
500 x 152 x
77 mm
19.69” x 5.98” x 3.03” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +50°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10 to 100% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
Storage Humidity
10 to 100% RH (Non-Condensing)
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Output voltage limited, 600Vdc
|
Overload / Overcurrent
Output power limited, 520W(Typ)
|
Over Temperature
Driver Over Temperature: Output power derating, not less than 20% in the worst case, auto-recovery when the fault is clear.
LED Fixtures Over Temperature: Output power derating, not less than 20% in the worst case, auto-recovery when the fault is clear |
Short Circuit
Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
IP66
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
475khrs. at ta=+45°C Telcordia SR-332
|
Expected Cap Life Time
50,000 hours applicable for 220Vac to 400Vac(50/60Hz) @100% of load, @ ta 45°C
|
Safety Certificate
ENEC
—IEC/EN61347-2-13 electronic control gear for LED Modules, independent type. —IEC/EN62384 DC or AC supplied electronic control gear for LED modules. CE Declaration of Conformity. CB report. |
Electrical Safety
-
|
CE
-
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Radiated Emission: EN55015 Test at 230Vac/400Vac
Conducted Emission: EN55015 Test at 230Vac/400Vac |
Immunity
EN55015
|
Harmonic Current Emissions
EN61000-3-2
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
200-550V
600W
2A
198-440Vac
60-200V
130W
0.2-1.05A
198-264Vac
35-105V
75W
0.2-1.05A
198-264Vac
18-52.4V
55W
1.4A
254-528Vac