Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
75-152V
320W
2.8A
249-528Vac
240 x 100 x 38 mm
9.45” x 3.94” x 1.50”
1.85 kg (4.08 lb)
75-152V
320W
2.8A
249-528Vac
240 x 100 x 38 mm
9.45” x 3.94” x 1.50”
1.85 kg (4.08 lb)
Output Current
2.8A
|
Output Voltage
75-152V
|
Output Voltage Range
75-152Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
320W
|
Output Current Adjustment Range
1.05-2.8A
|
Max Output Voltage
170Vdc
|
Buffering Time
-
|
Line Regulation
± 1% (@ 277-480Vac input)
|
Load Regulation
± 3% (@ Min-Max output voltage)
|
PARD
-
|
Start-up Time
1000ms max. @ 277-480Vac (full load)
|
Hold-up Time
16ms typ. @ 277-480Vac (full load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
277-480Vac
|
Input Voltage Range
249-528Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.5A @ 277Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
91.5% @ 2.8A, 277Vac, 93.5% @ 2.8A, 347Vac, 93.5% @ 2.8A, 480Vac
|
Max Inrush Current
-
|
Charging Time
-
|
Power Factor at 100% load
> 0.9 @ 50% Load , 277-480Vac
>=0.95 @ Full Load , 277-480Vac |
Leakage Current
< 0.75mArms @ 480Vac
|
Nominal Current
-
|
Total Harmonic Distortion
<20%@ Load >50% , 277-480Vac
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminum
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24dBA class A
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.85 kg (4.08 lb)
|
Dimensions
240 x 100 x
38 mm
9.45” x 3.94” x 1.50” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +55°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
5 to 95% RH (Non-Condensing)
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
170Vrms Auto-Recovery when the fault is removed
|
Overload / Overcurrent
Reduce output current. Auto-Recovery when the fault is removed
|
Over Temperature
Reduce output current. Auto-Recovery when the fault is removed
|
Short Circuit
Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
-
|
Electrical Safety
UL 8750, UL class P
|
CE
-
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
-
|
Immunity
-
|
Harmonic Current Emissions
-
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
Common Mode: 6kV/12ohm; Differential Mode: 6kV/2ohm,
1.2/50μs Combination Wave ANSI C82.77-5 CAT C low |
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
35-150V
75W
0.2-1.05A
198-264Vac
80-310V
170W
0.2-1.05A
198-264Vac
200-550V
600W
2A
198-440Vac
60-200V
130W
0.2-1.05A
198-264Vac