Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
20-50V
40W
0.35-1.05A
99-305Vac
280 x 30 x 25.4 mm
11.02” x 1.18” x 1.00”
0.22 kg (0.49 lb)
20-50V
40W
0.35-1.05A
99-305Vac
280 x 30 x 25.4 mm
11.02” x 1.18” x 1.00”
0.22 kg (0.49 lb)
Output Current
0.35-1.05A
|
Output Voltage
20-50V
|
Output Voltage Range
20-50Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
40W
|
Output Current Adjustment Range
0.35-1.05A
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 1% (@ 110-277Vac input, for 800mA-1050mA output current)
|
Load Regulation
± 5% (@ Min-Max output voltage, for 800mA-1050mA output current)
|
PARD
-
|
Start-up Time
1500ms max. @ 110-277Vac
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
110-277Vac
|
Input Voltage Range
99-305Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
0.43A @110Vac
0.2A @277Vac |
Input Power (Standby Mode)
0.5W @ 120Vac, 1W @ 277Vac, Dim to off
|
Efficiency at 100% load
90% @ 277Vac
|
Inrush Current
25A/50us @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.9 @ full load
|
Leakage Current
< 0.75mA
|
Nominal Current
-
|
Total Harmonic Distortion
THD < 20% with load ≥ 50% @ 110-277Vac input
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Metal sheet, Color: Natural
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
Terminal, 2&3-pole (Line/Neutral)&(PE/DALI1/DALI2), Conductor 0.5~1.5 mm² , Strip length 8.5…9.5mm
|
|
Output Terminal
Terminal, 2-pole (LED+/LED-), Conductor 0.5~1.5 mm² , Strip length 8.5…9.5mm
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.22 kg (0.49 lb)
|
Dimensions
280 x 30 x
25.4 mm
11.02” x 1.18” x 1.00” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-30°C to +50°C
|
Storage Temperature
-30°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Max. 60V, Auto-Recovery when the fault is removed
|
Overload / Overcurrent
-
|
Over Temperature
Auto-Recovery when the fault is removed
|
Short Circuit
Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
Auto-Recovery when the fault is removed
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
500,000 hrs.@ 50°C ambient temperature as per Telcordia SR-332
|
Expected Cap Life Time
50,000 hrs. at lifetime case temperature
|
Safety Certificate
-
|
Electrical Safety
UL8750 - Light Emitting Diode (LED) Equipment for Use in Lighting Products
UL/cUL (cRUus) to UL8750 and CAN/CSA-C22.2 No. 250.13 Type TL (75/65 deg. C) Class 2 of UL 1310 SELV |
CE
-
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
RoHS Directive Compliant
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
47CFR FCC Part 15, Subpart B, Class A
|
Immunity
-
|
Harmonic Current Emissions
-
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
ANSI C62.41-Category A1 with a 2.5kV/100kA ring wave, Criteria A (Normal performance within the specification limits)
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
16-54V
30W
0.15-1.05A
108-305Vac
16-54V
50W
0.35-1.4A
108-305Vac
20-54V
80W
0.7-2.1A
108-305Vac
20-50V
40W
0.35-1.05A
99-305Vac