Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
60W
2.5A
108-305 Vac
241.3 x 43.1 x 30 mm
9.50” x 1.70” x 1.18”
0.6 kg (1.32 lb)
24V
60W
2.5A
108-305 Vac
241.3 x 43.1 x 30 mm
9.50” x 1.70” x 1.18”
0.6 kg (1.32 lb)
Output Current
2.5A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
60W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 1%
|
Load Regulation
± 3%
|
PARD
-
|
Start-up Time
< 1.0s
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50 ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
120-277 Vac
|
Input Voltage Range
108-305 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
0.59 typ.
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
87% typ. @ 230 Vac
|
Inrush Current
>50% Duration 50 A/ 200 us
|
Charging Time
-
|
Power Factor at 100% load
> 0.95
|
Leakage Current
< 0.7mA @ 230Vac
|
Nominal Current
-
|
Total Harmonic Distortion
Meet IEC 61000-3-2 Class C
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Metal sheet
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
Line: Black, Neutral: White, Wire Length 300mm
|
|
Output Terminal
Positive: Red, Negative: Black, Wire Length 300mm
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.6 kg (1.32 lb)
|
Dimensions
241.3 x 43.1 x
30 mm
9.50” x 1.70” x 1.18” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +55°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
5 to 95% RH (Non-Condensing)
|
Operating Altitude
< 2,000m
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Auto-Recovery when the fault is removed
|
Overload / Overcurrent
Auto-Recovery when the fault is removed
|
Over Temperature
Auto-Recovery when the fault is removed
|
Short Circuit
Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
850,000 hrs. @ta: +45°C (as per Telcordia SR-332 , total failure rate less than 10% )
|
Expected Cap Life Time
50,000 hrs. at lifetime case temperature
|
Safety Certificate
-
|
Electrical Safety
UL: UL 8750, Class P, type “HL”. Class 2 Output
CSA: CAN/CSA C22.2 No.250.13 CB scheme: IEC 61347-1, IEC 61347-2-13, IEC 60335-1, IEC 60335-2-89 and Annex BB, IEC 60335-2-24 and Annex CC, SELV Output CCC: GB 17625.1-2012, GB/T 17743-2017, GB 19510.1-2009, GB 19510.14-2009 |
CE
In conformance with : Low Voltage Directive 2014/35/EU ; EMC Directive 2014/30/EU ; RoHS Directive 2011/65/EU+ (EU) 2015/863 and Erp Directive 2009/125/EC Implementing measure Commission Regulation (EU) 2019/2020.
|
Medical Safety
-
|
Galvanic Isolation
Input: 3000 Vac
Output : 500 Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with : Elecrtical Equipment (Safety) Regulations 2016; Electromagnetic Compatibility Regulations 2016 and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (as amended 2019,2020)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Compliance to BS EN/ EN 55015 & FCC Part 15 Class A
|
Immunity
Compliance to BS EN/ EN 61547
|
Harmonic Current Emissions
EN 61000-3-2 Class C (230Vac @ 100% load)
|
Voltage Fluctuation and Flicker
IEC 61000-3-3 Pst ≤ 1.0; dmax ≤ 4% ; Plt ≤ 0.65 ; dc ≤ 3.3% ; Tmax ≤ 500ms
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
200-550V
600W
2A
198-440Vac
150-550V
1200W
2A
187-528 Vac
18-52.4V
55W
0.6-1.4A
108-305 Vac
80-310V
170W
0.2-1.05A
198-264Vac