24V
240W
10A
18-30 Vdc
124 x 38 x 117 mm
4.88” x 1.50” x 4.61”
0.52 kg (1.15 lb)
24V
240W
10A
18-30 Vdc
124 x 38 x 117 mm
4.88” x 1.50” x 4.61”
0.52 kg (1.15 lb)
Output Current
10A
|
Output Voltage
24V
|
Output Voltage Range
17.5-29.5Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
240W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
15 s, 30 s, 45 s, 1 min, 3 min, 5 min, 10 min, 20 min, 30 min, ∞
|
Line Regulation
-
|
Load Regulation
-
|
PARD
-
|
Start-up Time
-
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
7 seconds
|
Power Boost Recovery Time
5 seconds
|
Nominal Input Voltage
24 Vdc
|
Input Voltage Range
18-30 Vdc
|
Max Input Voltage
-
|
Nominal Input Frequency
-
|
Input Frequency Range
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
-
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
98% typ.
|
Inrush Current
-
|
Charging Time
< 9 hr ± 1 hr (2 A charging current for 24 V/12 AH battery)
|
Power Factor at 100% load
-
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 40 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input / Output: AWG 18-8 (Load: 0-5 A), AWG 14-8 (Load: 5-10 A)
Battery: AWG 18-8 (Load: 0-5 A), AWG 14-8 (Load: 5-10 A) Signal: AWG 24-12 |
|
Protection Structure
-
|
|
Terminal
Input / Output: 4 Pins
Battery: 2 Pins Signal: 8 Pins Temperature Sensor & Rx/Tx: 4 Pins (CVILUX CP3504P1H00-NH) |
|
Unit Weight
0.52 kg (1.15 lb)
|
Dimensions
124 x 38 x
117 mm
4.88” x 1.50” x 4.61” |
Vibration (Operating)
EN 60068-2-64 (Wind Power Application)
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 60°C de-rate power by 2.5% / °C (when battery is fully charged) If the battery is not fully charged at max load, it is recommended that the surrounding air temperature should not exceed 50°C.
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30 G (300 m/s²) for a duration of 18 ms, 1 time per direction, 2 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, 10 Hz to 500 Hz @ 30 m/s² (3 G peak); 60 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 6,000 m (Approvals apply only up to 5,000 m)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Auto Recovery
|
Overload / Overcurrent
Normal Operation: Auto Recovery
Battery Operation: Latch off |
Over Temperature
Normal Operation: Auto Recovery
Battery Operation: Latch off |
Short Circuit
-
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
Class III
|
Input Polarity Protection
Yes
|
Battery Polarity Protection
Yes
|
Wrong Battery Voltage Protection
Yes, 30 Vdc Max (the maximum voltage that will not cause damage to the unit)
|
Deep Discharge Protection
Yes (21 V typ.)
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
Yes
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1
TUV Bauart: EN 62368-1 UL/cUL recognized: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 (File No. E131881) EAC: TP TC 002/2011 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Power Port to Housing: 500 Vac
Signal Port to Housing: 500 Vac Power Port to Signal Port: 500 Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
CE & RE
EN/BS EN 61000-6-4, EN 61204-3 |
Immunity
EN/BS EN 61000-6-2, EN 61204-3
|
Harmonic Current Emissions
-
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
Nominal Battery Voltage
24 Vdc, SLA Sealed lead acid battery
2 x 12 Vdc, SLA Sealed lead acid battery in series |
Battery Voltage Range
-
|
Battery Capacity
3.4 AH ~ 100 AH
|
Battery Charging Mode
-
|
End of Charge Voltage
27.6 V
|
Battery Fuse
-
|
Battery Discharging Voltage Range
21 Vdc ... 27.6 Vdc
30 Vdc Max (the maximum voltage that will not cause damage to the unit) |
Battery Charging Current
0.5 A, 1 A, 1.5 A, 2 A (typ.) (constant current)
|
Battery Current Consumption
< 200 mA
|
Discharging Current
-
|
Recommended Charging Voltage
-
|