Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
120W
5A
90-264 Vac
76.2 x 50.8 x 31 mm
3.00” x 2.00” x 1.22”
0.14 kg (0.31 lb)
24V
120W
5A
90-264 Vac
76.2 x 50.8 x 31 mm
3.00” x 2.00” x 1.22”
0.14 kg (0.31 lb)
Output Current
5A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
120W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
0.5%
|
Load Regulation
1%
|
PARD
150 mVpp @≥ 25 °C
450 mVpp @ ≥ -30 °C |
Start-up Time
1000 ms @ 115 Vac
500 ms @ 230 Vac |
Hold-up Time
20 ms @ 100% load, with nominal input range
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ with 5-100% load change, (50% duty @ 5 Hz & 10 KHz, 2.5 A/us slew rate )
|
Start-up with Capacitive Loads
8000 uF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
150 W
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
40 ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.3 A @ 115 Vac
0.9 A @ 230 Vac |
Input Power (Standby Mode)
< 0.21 W @ 115 Vac & 230 Vac
|
Efficiency at 100% load
92.0% @ 115 Vac
94.0% @ 230 Vac |
Max Inrush Current
60 A @ 230 Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.98 @ 115 V/60 Hz, full load
|
Leakage Current
0.1 mA @ NC, 1.0 mA @ SFC
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Open Frame
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
JST, B2P3-VH(LF)(SN) or equivalent
|
|
Output Terminal
JST : B4P-VH(LF)(SN) or equivalent
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.14 kg (0.31 lb)
|
Dimensions
76.2 x 50.8 x
31 mm
3.00” x 2.00” x 1.22” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-30°C to +70°C (-40°C cold start )
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Temperature Power De-rating: Linear power derating from 100% load at 50°C to 50% load at 70°C with 2.5%/°C
< 120Vac de-rate power by 0.83% / Vac |
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
5-500 Hz, 2.09 Grms, 20 minute for each three axis
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa) ( 4000 meters for IEC 60335-1, IEC 61558-1 )
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Corrosion
-
|
Overvoltage
Main output 110-150% of rated normal voltage, Latch mode
|
Overload / Overcurrent
Main output 105-185% of rated current , Hiccup Mode
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I & II
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
-
|
Electrical Safety
IEC60950-1 CB report
IEC62368-1 CB report (Ed.2-2014 & Ed.3-2018) TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1 Home Appliance (for 12 V & 24 V model): IEC60335-1 CB report IEC61558-1 /-2-16 CB report TUV EN 60335-1 TUV EN 61558-1 /-2-16 |
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
|
Medical Safety
IEC60601-1 CB report
TUV EN60601-1 ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1 |
Galvanic Isolation
Input to/Output (2XMOPP: 4000 Vac
Input to/Ground (1XMOPP): 2000 Vac Output to/Ground(1XMOPP): 1500 Vac (Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 Regulations 2016 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
IEC60950-1 CB report
IEC62368-1 CB report TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1 |
SIL3
-
|
Emission
EN55032, CISPR 32 AS/NZS CISPR32 & CISPR11 Class B Compliance to EN55014-1, CISPR 14-1, AS/NZS CISPR 14 Class B
Note: Class A Radiated Emission for Class II connection without earth connection |
Immunity
-
|
Harmonic Current Emissions
IEC 61000-3-2 Meet Class A limit
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|