Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
200W
0-8.34A
90-264 Vac
101.6 x 50.8 x 28.5 mm
4.00” x 2.00” x 1.12”
0.21 kg (0.46 lb)
24V
200W
0-8.34A
90-264 Vac
101.6 x 50.8 x 28.5 mm
4.00” x 2.00” x 1.12”
0.21 kg (0.46 lb)
Output Current
0-8.34A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
200W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
1%
|
Load Regulation
2%
|
PARD
-
|
Start-up Time
1,000 ms with AC turn on
|
Hold-up Time
12 ms @ 180W load, with nominal input range
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10 % @ with 5-100% load change,
(50% duty @ 10 Hz & 10 KHz, 0.5 A/us slew rate ) |
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
1 % pk-pk Vrated or 150 mV which is larger at rated load
|
LED System Voltage Range in CC Mode
-
|
Rise Time
<50 ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
2.5 A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
93% @ 115 Vac
94.7% @ 230 Vac |
Max Inrush Current
60 A at 264 Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.95 at 115 V & 230 Vac / 50 Hz, full load
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Open frame
|
|
Indicator
-
|
|
Cooling System
Convection / Force air
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
Input: JST, B2P3-VH or equivalent
Output: JST : B6P-VH-B (LF) (SN) or equivalent |
|
Unit Weight
0.21 kg (0.46 lb)
|
Dimensions
101.6 x 50.8 x
28.5 mm
4.00” x 2.00” x 1.12” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-30 °C to +70 °C
|
Storage Temperature
-40 °C to +85 °C
|
Power De-rating
Linear power derating from 100% load at 45 °C to 50% load at 70 °C with 2 %/°C
|
Operating Humidity
5-95 % RH (Non-condensing)
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
5 – 500 Hz, 2 Grms, 15 minute for each three axis
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Main output 125 % of rated normal voltage, latch mode
|
Overload / Overcurrent
Main output 140% of rated current, Hiccup Mode
|
Over Temperature
Latch mode for main output
|
Short Circuit
Hiccup mode (Non-latching, auto-recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I & II (Applicable to Class II medical equipment which needs to be evaluated in the end product assembly.)
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
-
|
Electrical Safety
IEC60950-1 CB report
IEC62368-1 CB report TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1 Household: IEC60335-1 CB report IEC61558-1 & -2-16 CB report TUV EN 60335-1 TUV EN 61558-1 & -2-16 |
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
|
Medical Safety
IEC60601-1 CB report
TUV EN60601-1 (2006) ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1 |
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground (1XMOPP): 1500 Vac Output to/Ground (1XMOPP): 1500 Vac (Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN55011/EN55032,FCC Title 47:Class B for Class I Note: Class B Radiated Emission for Class II connection without earth connection needs to add EMI filter. Please consult with DELTA for detail information.
|
Immunity
-
|
Harmonic Current Emissions
IEC61000-3-2 Meet Class D limit
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|