Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
650W
0-27.1A
90-264 Vac
152.4 x 101.6 x 40 mm
6.00” x 4.00” x 1.57”
(0.00 lb)
24V
650W
0-27.1A
90-264 Vac
152.4 x 101.6 x 40 mm
6.00” x 4.00” x 1.57”
(0.00 lb)
Output Current
0-27.1A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
650W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
1%
|
Load Regulation
2%
|
PARD
-
|
Start-up Time
2000 ms with AC turn on
|
Hold-up Time
20 ms @ 450 W load, with nominal input range
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 0-50% & 50-100% load change
|
Start-up with Capacitive Loads
6000 uF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
1.0% Vrated pk-pk @ rated load (450 W)
1.5% Vrated pk-pk @ rated load (650 W) |
LED System Voltage Range in CC Mode
-
|
Rise Time
<50 ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
|
Nominal DC Input Voltage
47-63Vdc
|
DC Input Voltage Range
-
|
Input Current
8.0 A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
94.5% @ 115 Vac
95.5% @ 230 Vac |
Max Inrush Current
40 A @ 264 Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.95 @ 115 Vac / 50 Hz, 230 Vac / 50 Hz, full load
|
Leakage Current
0.3 mA @ NC, 1 mA @ SFC
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
-
|
|
Indicator
-
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
(0.00 lb)
|
Dimensions
152.4 x 101.6 x
40 mm
6.00” x 4.00” x 1.57” |
Vibration (Operating)
5-500 Hz, 2 Grms, 15 minute for each three axis
|
Shock Test (Operating)
-
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Convection
Linear power de-rate from 100% load at 50°C, to 53.3% load at 70°C Force Air Linear power de-rate from 100% load at 50°C, to 50% load at 70°C |
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Main output 140% of rated normal voltage, Latch Mode Standby 125% of rated voltage, Latch Mode
|
Overload / Overcurrent
750 W for over 750 ms max Standby 3.2 A max with Hiccup Mode(Non-Latching, Auto-Recovery)
|
Over Temperature
Latch Mode for Main output
|
Short Circuit
Hiccup Mode for Main output and Standby (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
IEC60601-1 CB report
TUV EN60601-1 A11/A12 CAN/CSA-C22.2 No. 60601-1 + ANSI/AAMI ES 60601-1 IEC60950-1 CB report IEC62368-1 CB report TUV EN62368-1 UL62368-1 and CAN/CSA C22.2 No. 62368-1 IEC60335-1 CB report (12 V & 24 V Model) TUV EN60335-1 (12 V & 24 V Model) IEC61558-1 CB report (12 V & 24 V Model) TUV EN61558-1/-2-16 (12 V & 24 V Model) |
Electrical Safety
ITE
IEC60950-1 CB report IEC62368-1 CB report TUV EN62368-1 UL62368-1 and CAN/CSA C22.2 No. 62368-1 Household IEC 60335-1 CB report TUV EN 60335-1 IEC 61558-1 CB report |
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
|
Medical Safety
IEC60601-1 CB report
TUV EN60601-1 CAN/CSA-C22.2 NO.60601-1 + ANSI/AAMI ES 60601-1 |
Galvanic Isolation
Input to/Output (2 X MOPP): 4000 Vac
Input to/Ground (1 X MOPP) : 1500 Vac Output to/Ground(1 X MOPP) : 1500 Vac ( Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002Regulations 2016 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
IEC60950-1 CB report
IEC62368-1 CB report TUV EN62368-1 UL62368-1 and CAN/CSA C22.2 No. 62368-1 |
SIL3
-
|