Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
5V
35W
7A
85-264Vac
98 x 97 x 38 mm
3.86” x 3.82” x 1.50”
0.18 kg (0.40 lb)
Model | Description |
---|---|
PMC-05V035W1AJ | IP20 connector |
5V
35W
7A
85-264Vac
98 x 97 x 38 mm
3.86” x 3.82” x 1.50”
0.18 kg (0.40 lb)
Model | Description |
---|---|
PMC-05V035W1AJ | IP20 connector |
Output Current
7A
|
Output Voltage
5V
|
Output Voltage Range
|
Output Voltage Adjustment Range
4.75-5.5Vdc
|
Output Power
35W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 0.5% (@ 85-264Vac input, 100% load)
|
Load Regulation
< 1.0% (@ 85-264Vac input, 0-100% load)
|
PARD
< 70mVpp
|
Start-up Time
< 2500ms @ nominal input (100% load)
|
Hold-up Time
> 15ms @ 115Vac,
> 80ms @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 0-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
Start-up with Capacitive Loads
6,600µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 30ms @ nominal input (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
125-250Vdc
|
DC Input Voltage Range
125-375Vdc
|
Input Current
< 0.9A @ 115Vac,
< 0.8A @ 230Vac |
Input Power (Standby Mode)
-
|
Efficiency at 100% load
> 78% @ 115Vac,
> 79% @ 230Vac |
Max Inrush Current
< 30A @ 115Vac,
< 60A @ 230Vac |
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 1mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
0% load: < 0.3W @ 115Vac, < 0.7W @ 230Vac
100% load: < 9.9W @ 115Vac, < 9.3W @ 230Vac |
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 40dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.18 kg (0.40 lb)
|
Dimensions
98 x 97 x
38 mm
3.86” x 3.82” x 1.50” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-10°C to +70°C
|
Storage Temperature
-25°C to +85°C
|
Power De-rating
> 50°C de-rate power by 2.5% /°C
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 3 times per direction, 18 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 20 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 3,000 Meters (9,840 ft)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Corrosion
-
|
Overvoltage
< 6.5V ±10%, SELV output, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Overload / Overcurrent
> 120% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20 (PMC-05V035W1AJ)
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
(I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C) |
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart : EN 62368-1
UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB Scheme : IEC 60950-1, IEC 62368-1 KC : K 60950-1 CCC: GB/T9254, GB17625.1 and GB4943.1 仅适用于海拔 2000m 以下地区安全使用 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
Certificates for Other Countries
-
|
BIS
-
|
KC
K 60950-1 (for PMC-05V035W1AA)
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032, KN 32 (for PMC-05V035W1AA),
FCC Title 47: Class B, GB 9254 |
Immunity
Generic Standards: EN 55024, KN35
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
150W
6.5A
90-264 Vac
36V
600W
16.6A
90-264 Vac
12V
240W
20A
90-264 Vac
12V
600W
50A