24V
600W
25A
85-264Vac
190 x 120 x 61 mm
7.48” x 4.72” x 2.40”
1.4 kg (3.09 lb)
24V
600W
25A
85-264Vac
190 x 120 x 61 mm
7.48” x 4.72” x 2.40”
1.4 kg (3.09 lb)
Output Current
25A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
21.6-27.6Vdc
|
Output Power
600W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.4% typ. (@ 115 & 240Vac input, 100% load)
|
Load Regulation
± 0.5% typ. (@115 & 240Vac input, 100% load)
|
PARD
< 150mVpp @ 0°C to 70°C,
180mVpp typ. @ -20°C to 0°C |
Start-up Time
500ms typ. @ 230Vac (100% load)
|
Hold-up Time
20ms typ. @ 115Vac & 230Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 50-100% load
|
Start-up with Capacitive Loads
10,000μF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50ms @ 115Vac & 230Vac (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
6A typ. @ 115Vac, 3A typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
90.0% typ. @ 115Vac, 92.0% typ. @ 230Vac
|
Inrush Current
40 A typ. @ 230 Vac
|
Charging Time
-
|
Power Factor at 100% load
0.99 typ. @ 100Vac, 0.97 typ. @ 200Vac
|
Leakage Current
< 0.75mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
SGCC
|
|
Indicator
-
|
|
Cooling System
Built-in Fan
|
|
Input Terminal
M3.5 x 3 Pins (Rated 300Vac/20A)
|
|
Output Terminal
M4 x 4 Pins (Rated 300Vac/25A)
|
|
Signal Terminal
Signal Connector: JST S8B-PHDSS(LF)(SN)
Mating connector: JST PHDR-08VS or equivalent |
|
Noise Sound Pressure Level (SPL)
< 60dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.4 kg (3.09 lb)
|
Dimensions
190 x 120 x
61 mm
7.48” x 4.72” x 2.40” |
Vibration (Operating)
IEC60068‐2‐6, Sine Wave: 10Hz to 55Hz @19.6m/s2(2G peak);
10min per cycle, 60min per axis for all X,Y,Z direction |
Shock Test (Operating)
IEC60068‐2‐27, Half Sine Wave: 10G for a duration of 11ms, 3 shocks for each 3 directions
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-30°C to +75°C
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 110Vac de-rate power by 0.8% / 1V |
Operating Humidity
20-95% RH
|
Shock Test (Non-Operating)
IEC60068‐2‐27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
Vibration (Non-Operating)
IEC60068‐2‐6, Random: 5Hz to 500Hz (2.09Grms);
20min per axis for all X,Y,Z direction |
Storage Humidity
-
|
Operating Altitude
5,000 Meters
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Corrosion
-
|
Overvoltage
27.6-33.6V, SELV Output, Latch-off Mode
|
Overload / Overcurrent
105~160%; Constant current limit with automatic recovery
|
Over Temperature
Latch-off Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with PE connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs as per Telcordia SR-332
I/P: 115Vac, O/P: 100% Load, Ta: 25°C) |
Expected Cap Life Time
10 years (115 Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
TUV Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 N 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) CB scheme: IEC 60950-1, IEC 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.8KVac Output to Ground: 0.5KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
CISPR 32, EN/BS EN 55032
Compliance to FCC Title 47, VCCI, EN 55011 : Class B |
Immunity
EN/BS EN 55035, KN35
Compliance to EN 61000-6-2 |
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2 Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
IEC 61000-4-2: Level 4 Criteria A
Air Discharge: 15kV Contact Discharge: 8kV |
Radiated Immunity
-
|
EFT
IEC 61000-4-4: Level 3 Criteria A
2kV |
Surge
IEC 61000-4-5: Level 4 Criteria A
Common Mode: 4kV Differential Mode: 2kV |
Conducted Immunity
IEC 61000-4-6 : Level 3 Criteria A
150kHz-80MHz, 10Vrms |
Magnetic Field
IEC 61000-4-8 : Level 4 Criteria A
30A/Meter |
Voltage Dips
IEC 61000-4-11 :
0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C 70% residual; 25 cycle, Criteria C |
Component Power Supply for General Use
-
|
24V
600W
25A
85-264Vac
12V
600W
50A
85-264Vac
48V
600W
12.5A
85-264Vac
24V
504W
21A
90-264Vac