48V
600W
12.5A
85-264Vac
215 x 120 x 61 mm
8.46” x 4.72” x 2.40”
1.54 kg (3.40 lb)
48V
600W
12.5A
85-264Vac
215 x 120 x 61 mm
8.46” x 4.72” x 2.40”
1.54 kg (3.40 lb)
Output Current
12.5A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
43.2-52.8Vdc
|
Output Power
600W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
<192mV (@115-264Vac input, 100% load)
|
Load Regulation
<300mV (@115-264Vac input, 100% load)
|
PARD
<300mVpp
|
Start-up Time
<500ms @115Vac & 230Vac (100% load)
|
Hold-up Time
<20ms @115Vac & 230Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 115-264Vac input, 10-100%
Slew Rate: 0.1A/µs, 50% duty cycle @ 5Hz to 1kHz) |
Start-up with Capacitive Loads
10,000µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
<100ms @115Vac & 230Vac (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
test
|
DC Input Voltage Range
120-375Vdc
|
Input Current
<6.50A @115Vac, <3.20A @230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
>87% @115Vac, >90% @230Vac
|
Inrush Current
<20A @ 115Vac & <40A @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
>0.98 @ 115Vac, >0.96 @ 230Vac
|
Leakage Current
< 3.0 mA / 4.0 mA @ 264 Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
SECC
|
|
Indicator
Green LED DC OK
|
|
Cooling System
Forced Cooling (Built-in Fan)
|
|
Input Terminal
M3.5 x 3 Pins (Rated 300V/20A)
|
|
Output Terminal
M3.5 x 4 Pins (Rated 300V/25A)
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
<52dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
Input AWG 14-12
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.54 kg (3.40 lb)
|
Dimensions
215 x 120 x
61 mm
8.46” x 4.72” x 2.40” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S² for a duration of 18ms
1 times per direction, / 2 times in total |
Vibration (Non-Operating)
IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak);
displacement of 0.35mm; 20 min per axis for all X,Y,Z |
Storage Humidity
-
|
Operating Altitude
0 to 3,000 Meters (9,840 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Corrosion
-
|
Overvoltage
<69.3V, SELV Output, Latch Mode
|
Overload / Overcurrent
>150% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery) |
Over Temperature
< 80°C Surrounding Air Temp@ 100% load, Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed).
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with PE* connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
>700,000 hrs. as per Telcordia SR-332
I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 62368-1
UL/cUL recognized UL60950-1 and CSA C22.2 No. 60950-1, UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme IEC 60950-1, IEC 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 2.0Kvac Output to Ground: 0.5KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47,
VCCI: Class B |
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-2
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
48V
150W
3.3A
90-264 Vac
24V
600W
25A
90-264 Vac
24V
211.2W
8.8A
180-264 Vac
48V
1200W
-
85-264 Vac