Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
48V
600W
12.5A
90-264 Vac
225 x 124 x 41 mm
8.86” x 4.88” x 1.61”
1.2 kg (2.65 lb)
48V
600W
12.5A
90-264 Vac
225 x 124 x 41 mm
8.86” x 4.88” x 1.61”
1.2 kg (2.65 lb)
Output Current
12.5A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
43.2-52.8 Vdc
|
Output Power
600W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% typ. @ 115 Vac & 230 Vac
|
Load Regulation
±0.5% typ.
|
PARD
< 150 mVpp @ 0°C to 70°C
450 mVpp typ. @ -30°C to 0°C |
Start-up Time
500 ms typ. @ 115 Vac & 230 Vac
|
Hold-up Time
18 ms typ. @ 115 Vac & 230 Vac
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 & 230 Vac input, 10-100% load
(Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz) |
Start-up with Capacitive Loads
5,000 µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
600.0 W
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30 ms typ. @ 115 Vac & 230 Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
127-375 Vdc
|
Input Current
6.0 A typ. @ 115 Vac
3.0 A typ. @ 230 Vac |
Input Power (Standby Mode)
1.5 W typ. @ 230 Vac
|
Efficiency at 100% load
93.0% typ. @ 230 Vac
|
Inrush Current
45 A typ. @ 230 Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.96 @ 115 Vac & 230 Vac
|
Leakage Current
< 0.8 mA @ 240 Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
SGCC / SGCC
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Force Cooling
|
|
Input Terminal
M3.5 x 9 Pins (Rated 300 V / 20 A)
|
|
Output Terminal
M3.5 x 9 Pins (Rated 300 V / 20 A)
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
AWG 14-10
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.2 kg (2.65 lb)
|
Dimensions
225 x 124 x
41 mm
8.86” x 4.88” x 1.61” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2G ; 10 min per cycle, 60 min for each axis (X,Y,Z)
|
Shock Test (Operating)
-
|
Operating Temperature
-30°C to +70°C ( -40°C Cold Start )
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 50°C de-rate power by 2% / °C
< 100Vac de-rate power by 1% / V (90% load @ 90 Vac) |
Operating Humidity
20 to 90% (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
|
Pollution Degree
3
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Corrosion
-
|
Overvoltage
52.8 V - 64.8 V
SELV Output Latch Mode |
Overload / Overcurrent
105 - 150% of rated load current, Auto-recovery
Continuous current limit Mode (Vo > 80%) |
Over Temperature
Auto-recovery
|
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Protection Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
T10 A / 250 V
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs as per Telcordia SR-332
I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
Expected Cap Life Time
10 years (230 Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
TUV Bauart: EN 62368-1, EN 60335-1
UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1, IEC 60335-1, IEC/EN 61558-1/-2-16 EAC: TP TC 004/2011 BSMI: CNS 15598-1 CCC: GB4943.1-2022 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 4.0 KVac
Input to Ground: 2.0 KVac Output to Ground: 1.25 KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, KS C 9832, AS/NZS CISPR32 & Compliance to FCC Title 47, EN/BS EN 55014-1 , EN/BS 61000-6-3 , EN/BS EN 61000-6-4 : Class B |
Immunity
EN/BS EN 55035, KS C 9835, & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6- 1 , EN/BS EN 61000-6-2
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A & Class D
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
48V
600W
12.5A
80-275Vac
48V
600W
12.5A
85-264Vac
48V
320W
6.7A
90-264 Vac
48V
240W
5A
90-264 Vac
48V
150W
3.3A
90-264 Vac