15V
51W
3.4A
85-264Vac
98 x 98 x 38 mm
3.86” x 3.86” x 1.50”
0.23 kg (0.51 lb)
** NRND **
PMT-15V50W1AA, PMT-15V50W1AG, PMT-15V50W1AH
Recommended Model: PMT-15V50W2BA
Model | Description |
---|---|
PMT-15V50W1AG | Enclosed, front face connector |
PMT-15V50W1AH | Enclosed, harness connector |
PML-15V50W1AA | L Frame, terminal block |
PML-15V50W1AG | L Frame, front face connector |
PML-15V50W1AH | L Frame, harness connector |
** NRND **
PMT-15V50W1AA, PMT-15V50W1AG, PMT-15V50W1AH
Recommended Model: PMT-15V50W2BA
15V
51W
3.4A
85-264Vac
98 x 98 x 38 mm
3.86” x 3.86” x 1.50”
0.23 kg (0.51 lb)
Model | Description |
---|---|
PMT-15V50W1AG | Enclosed, front face connector |
PMT-15V50W1AH | Enclosed, harness connector |
PML-15V50W1AA | L Frame, terminal block |
PML-15V50W1AG | L Frame, front face connector |
PML-15V50W1AH | L Frame, harness connector |
Output Current
3.4A
|
Output Voltage
15V
|
Output Voltage Range
|
Output Voltage Adjustment Range
13.5-16.5Vdc
|
Output Power
51W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 0.5% typ. (@ 115Vac & 230Vac input, 100% input)
|
Load Regulation
< 0.5% typ. (@ 115Vac & 230Vac input, 0-100% input)
|
PARD
< 150mVpp @ 25°C to 50°C,
< 300mVpp @ -10°C to 0°C |
Start-up Time
1,200ms typ.@ 115Vac,
500ms typ. @ 230Vac (100% load) |
Hold-up Time
20ms typ. @ 115Vac, 100ms typ. @ 230Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% (1000mVp-p)@ 0-100% load (Slew Rate: 0.1A/µS)
|
Start-up with Capacitive Loads
8,000μF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 30ms @ 115Vac & 230Vac (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Peak Power
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
< 1.10A @ 115Vac, < 0.65A @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
85.5% typ. @ 230Vac
|
Inrush Current
45A typ. @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 0.5mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium / SGCC
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.23 kg (0.51 lb)
|
Dimensions
98 x 98 x
38 mm
3.86” x 3.86” x 1.50” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-10°C to +70°C
|
Storage Temperature
-25°C to +85°C
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 1.33% / V (80% load @ 85Vac) |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Corrosion
-
|
Acoustic Noise
-
|
Overvoltage
17.25-20.25V, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery) |
Overload / Overcurrent
110-150% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery) |
Over Temperature
Non-Latching (Auto-Recovery)
|
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs as per Telcordia SR-332 I/P: 100Vac, O/P: 100% Load, Ta: 35°C)
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
TUV Bauart:EN 60950-1, EN/BS EN 62368-1
UL/cUL recognized:UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) CB scheme:IEC 60950-1, IEC 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
48V
1200W
-
85-264 Vac
24V
76.8W
3.2A
180-264 Vac
24V
150W
6.5A
90-264 Vac
48V
350.4W
7.3A
180-264 Vac