Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
36W
1.5A
90-264Vac
99 x 82 x 29 mm
3.90” x 3.23” x 1.14”
0.165 kg (0.36 lb)
Model | Description |
---|---|
PMT-24V35W2BAB | Single side conformal coating |
24V
36W
1.5A
90-264Vac
99 x 82 x 29 mm
3.90” x 3.23” x 1.14”
0.165 kg (0.36 lb)
Model | Description |
---|---|
PMT-24V35W2BAB | Single side conformal coating |
Output Current
1.5A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
21.6-26.4Vdc
|
Output Power
36W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% (@ 115Vac & 230Vac input)
|
Load Regulation
± 0.5% (@ 115Vac & 230Vac input)
|
PARD
< 150mVpp @ 0°C to 70°C
450mVpp typ. @ -30°C to 0°C |
Start-up Time
1,000ms typ. @ 115Vac
500ms typ. @ 230Vac |
Hold-up Time
16ms typ. @ 115Vac, 70ms typ. @ 230Vac
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
|
Start-up with Capacitive Loads
8,000µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30ms typ. @ 115Vac & 230Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
0.7A typ. @ 115Vac, 0.42A typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
88.5% typ. @ 230Vac
|
Max Inrush Current
45A typ. @ 230Vac (Cold Start)
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 0.5mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium / SGCC
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
AWG 18-12
Current rating can refer to page 6 “Wire AWG Table” |
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.165 kg (0.36 lb)
|
Dimensions
99 x 82 x
29 mm
3.90” x 3.23” x 1.14” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)
|
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
|
Operating Temperature
-30°C to +70°C (-40°C Cold Start)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 50°C de-rate power by 2% / °C
< 100Vac de-rate power by 1.33% / V (86.67% load @ 90Vac) |
Operating Humidity
20 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
|
Pollution Degree
3
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Corrosion
-
|
Overvoltage
26.4-33.6V SELV Output, Latch Mode
|
Overload / Overcurrent
110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with PE*4 connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25°C)
|
Expected Cap Life Time
10 years (230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16
cULus: UL 62368-1, CAN/CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 KC:K 60950-1 EAC: TP TC 004/2011 BSMI: CNS 14336-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output:4.0KVac
Input to Ground: 2.0 KVac Output to Ground: 1.25 KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
CISPR 32, EN/ BS EN 55032, KN 32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-4, EN/BS EN 61000-6-3 : Class B |
Immunity
EN/BS EN 55035, KN 35
Compliance to EN/ BS EN 55014-2, EN/ BS EN 61000-6-2, EN/ BS EN 61000-6-1 |
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
108W
4.5A
180-264 Vac
36V
240W
0.67A
90-264 Vac
36V
600W
16.6A
90-264 Vac
12V
240W
20A
90-264 Vac