工业电源
Click the link below to download the file.
Get your files as below link
Dowload link
48V
150W
3.125A
85-264Vac
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.53 kg (1.17 lb)
输出电流
3.125A
|
输出电压
48V
|
输出电压范围
|
输出电压调整范围
44-53Vdc
|
输出功率
150W
|
输出电流调整范围
|
最大输出电压
|
缓冲时间
-
|
线电压调整率
< 0.5% typ. (@ 85-264Vac, 100% load)
|
负载调整率
< 1% typ. (@ 85-264Vac, 0-100% load)
|
纹波电压
< 200mVpp
|
开机时间
< 3,000ms @ nominal input (100% load)
|
保持时间
> 30ms @ 115Vac & 230Vac (100% load)
|
动态回应
± 5% @ 85-264Vac input, 0-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
电容性负载启动
2,000μF Max @ 25°C (CC and CR mode)
1,000μF Max @ -10°C and 50°C (CC mode) 2,000μF Max @ -10°C and 50°C (CR mode) |
摇控开/关
-
|
保护设备
-
|
输入输出间电压骤降
-
|
残留波纹/PARD (20MHz)
-
|
残留波纹
-
|
最大功率
-
|
波纹与噪音
-
|
CC 型号 LED系统电压范围
-
|
升压时间
-
|
峰值功率持续时间
-
|
峰值功率回复时间
-
|
额定输入电压
100-240Vac
|
输入电压范围
85-264Vac
|
最大输入电压
-
|
额定输入频率
50-60Hz
|
输入频率范围
47-63Hz
|
额定直流输入电压
125-250Vdc
|
直流输入电压范围
125-375Vdc
|
输入电流
< 1.70A @ 115Vac,
< 1.00A @ 230Vac |
输入功率(待机模式)
-
|
100% 负载效率
> 89.0% @ 115Vac,
> 91.0% @ 230Vac |
最大涌入电流
< 20A @ 115Vac,
< 40A @ 230Vac |
充电时间
-
|
功率因数
> 0.99 @ 115Vac,
> 0.92 @ 230Vac |
漏电流
< 1.5mA @ 240Vac
|
额定电流
-
|
谐波失真总量
-
|
最大功率损耗
-
|
效率 @ 10% 负载
-
|
底座 / 外壳上盖
Aluminium
|
|
指示灯
Green LED DC OK
|
|
冷却方式
Convection
|
|
输入端
-
|
|
输出端
-
|
|
信号端
-
|
|
声压级(SPL)
< 40dBA
|
|
输入/输出端
-
|
|
信号
-
|
|
安装导轨
-
|
|
电线
-
|
|
保护结构
-
|
|
端子台
-
|
|
重量
0.53 kg (1.17 lb)
|
尺寸
178 x 97 x
38 mm
7.01” x 3.82” x 1.50” |
振动测试(运行状态)
-
|
防震测试(运行状态)
-
|
运行温度
-10°C to +70°C
|
储存温度
-25°C to +85°C
|
功率降级
> 50°C de-rate power by 2.5% / °C
|
运行湿度
5 to 95% RH (Non-Condensing)
|
防震测试(非运行状态)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 time per direction, 2 times in total
|
振动测试(非运行状态)
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 20 min per axis for all X, Y, Z direction
|
储藏湿度
-
|
运行高度
0 to 5,000 Meters (16,400 ft)
|
污染程度
2
|
碰撞试验(运行状态)
-
|
过压类别
ll
|
Corrosion
-
|
过压保护
< 63V, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
超负载/过电保护
> 120% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
过热保护
< 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
短路保护
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
极性反接保护
-
|
防护等级
-
|
防震保护
Class I with Primary Earth connection
|
输入端极性保护
-
|
电池极性保护
-
|
电池电压保护错误
-
|
深度放电保护
-
|
超负载保护
-
|
过电保护
-
|
内置保险丝
-
|
输入欠压保护
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C |
预计最长使用寿命
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
电气安全
SIQ Bauart: EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1 CCC: GB4943 UKCA: BS EN 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
医疗安全
-
|
电隔离
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
工业控制设备
-
|
危险场所/ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
机器电气设备
-
|
用於电率安装的电气设备
-
|
安全特低电压
SELV (IEC 60950-1)
|
海事
-
|
材料与部件
-
|
隔离电阻
-
|
PE 电阻
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
国家地区证书
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
24V
150W
6.5A
90-264 Vac
48V
76.8W
1.6A
180-264 Vac
24V
150W
6.25A
180-264 Vac
48V
350.4W
7.3A
180-264 Vac